Questions and Answers

  • L
    leechristineAug 19, 2025
    What to do if Command Light KNIGHT Lighting Equipment lights will not illuminate?
    • T
      Tracy GutierrezAug 19, 2025
      If the lights on your Command Light Lighting Equipment won't turn on, there are a few potential causes: * The lower stage might not be raised above the safety limit of 16 inches. If this is the case, raise the lower stage higher. * A circuit breaker may have tripped. Check the circuit breaker at the power supply. * The lamp filament could be broken, requiring a lamp replacement.
  • P
    perezrebeccaAug 21, 2025
    Why Command Light Lighting Equipment unit will not extend?
    • M
      Matthew BarkerAug 21, 2025
      If your Command Light Lighting Equipment unit isn't extending, it could be due to a couple of reasons: * There might be no power reaching the unit. In this case, check the power input connections. * The installation might be incorrect. Refer to the installation instructions to ensure proper setup.
  • P
    Paula WilsonAug 25, 2025
    What to do if Autopark button must be held in to park Command Light KNIGHT unit?
    • H
      Henry AdamsAug 25, 2025
      If you have to hold the Autopark button to park your Command Light Lighting Equipment unit, it could be due to: * A faulty or stuck nest switch. Check the nest switch ground and operation. The rubber boot may have shrunk and is holding in the switch. * Water in the electronics. Remove moisture from ground points and electronics. Remember, do not use a pressure washer to clean the unit.
  • D
    Deanna SharpAug 26, 2025
    What to do if Command Light KNIGHT unit will not nest?
    • M
      Monique MillsAug 26, 2025
      If your Command Light Lighting Equipment unit won't nest, consider these possibilities: * The upper stage might not be centered. Raise the lower stage higher than 16 inches and center the upper stage until the green light is illuminated. * The unit is being operated on a slope greater than 5°. Lower the lamp tree to horizontal. Use a pike pole to hold the unit level while lowering it to the nest position.
  • M
    Michael BakerAug 28, 2025
    Why Command Light Lighting Equipment upper stage will not rotate?
    • S
      sanchezgregoryAug 28, 2025
      If the upper stage of your Command Light Lighting Equipment isn't rotating, it could be because: * The lower stage isn't raised above the safety limit (16" above base). Raise the lower stage higher. * Rotation motor failure. Consult with factory.
  • D
    Derrick CurtisAug 30, 2025
    Why Command Light KNIGHT rotation coasts after switch is released?
    • A
      Anthony RobertsAug 30, 2025
      If the rotation coasts after the switch is released on your Command Light Lighting Equipment, the rotation belt may be loose. Adjust the belt to provide no more than ¼” slack.
  • L
    lblackwellSep 1, 2025
    Why Command Light Lighting Equipment Upper Actuator & Rotation start at the same time?
    • L
      Lisa BenjaminSep 1, 2025
      If the Upper Actuator & Rotation start at the same time on your Command Light Lighting Equipment, the down limit switch might be stuck or damaged. The aluminum plunger which activates the down limit switch should move freely. Verify proper switch operation.
  • G
    Gregory GutierrezSep 3, 2025
    What causes popping noise during Back Light Rotation in Command Light KNIGHT Lighting Equipment?
    • R
      ryan41Sep 3, 2025
      If you hear a popping noise during back light rotation in your Command Light Lighting Equipment, it could be due to switch boots stuck or a faulty rotation relay. Replace the switch boots. Contact factory for replacements parts.
  • K
    Katherine LewisSep 5, 2025
    Why won't my Command Light KNIGHT illuminate?
    • M
      Michael EvansSep 6, 2025
      Several factors can prevent your Command Light Lighting Equipment from illuminating. It could be that the lower stage is not raised above the safety limit of 16 inches, so raise the lower stage higher. The circuit breaker might have tripped, so check the circuit breaker at the power supply. There might be no power to the unit, so check the power supply operation and output. Lastly, the lamp filament might be broken, so replace the lamp.
  • X
    xavier60Sep 8, 2025
    How to fix Command Light KNIGHT if the unit will not extend?
    • R
      Raven RoblesSep 8, 2025
      If your Command Light Lighting Equipment unit won't extend, the issue might stem from a lack of power to the unit, so check the power input connections. Alternatively, the problem could be due to incorrect installation, so refer to the installation instructions.

Command Light KNIGHT Series Specifications

General IconGeneral
ModelKNIGHT Series
CategoryLighting Equipment
Light SourceLED
LengthVaries by model
Housing MaterialAluminum
Lens MaterialPolycarbonate
Power Source12-24V DC
Light OutputVaries by model
Voltage12-24V DC
Beam PatternFlood
IP RatingIP67