Maintenance
1. Maintenance Overview
Unless otherwise specified, perform adjustment and maintenance of this device only when the power is
turned off and the power supply has been disconnected. Only trained and skilled professionals should
modify or disassemble this device.
2. Regular Maintenance Procedures
Keep the workroom clean and dust-free at all times.
Ensure the device is fully powered off when not in use.
Cover the galvanometric lens when it is not in use.
Clean the worktable after use with a cloth wetted with more than 75% rubbing alcohol.
Never clean this device with abrasive or caustic cleansers, aerosol sprays, or enough water to enter any
electrical component. Always allow surfaces to fully dry before further use.
When removing dust from the device's vents using a vacuum, ONLY use the lowest power setting to
avoid damage to internal components.
No other servicing should be done by the operator. Do not attempt to service or replace other parts
yourself.
3. Troubleshooting Guidance
Correct the focus by adjusting the height of the laser arm.
Correct the software parameters if they are invalid or mistaken.
Have a technician fix or establish the connection between the laser and
the mainboard.
Have a technician fix or establish the connection between the laser and
its power supply.
If either the fiber laser source or its power supply has worn out, have a
technician replace them.
No Engraving
despite Laser Output
Confirm that the material can be safely engraved with this device.
Correct the focus by adjusting the height of the laser arm.
Adjust the software parameters to create greater intensity.
Have a technician check the control panel, scanning lens,
and their power supply. Correct any problems or replace the parts.
Have a technician check the fiber.
Have a technician check the fiber laser source and
the mainboard. Correct any problems or replace the parts.