Ȅ Notes when use Lobby mode.
z S/W1 : Set LOBBY mode Î SW1 “ON”.
z S/W2 : Set response of lobby SECUMAX DATA Î SW2 “ON”.
¾
This is for the system without SECUMAX.
¾
In caes of using CCU-310EV without SECUMAX, lobby’s SECUMAX DATA must be set “ON”.
Æ CCU-310EV collects data which LOBBY informs to SECUMAX.
Also, it works when opening the door during calling between LOBBY and household.
¾
If no intalled SECUMAX., calling might be calling problem due to lots of data stored
into the lobby.
Î If no SECUMAX., S/W2 must be “ON” to respond the data instead of SECUMAX.
z S/W3, S/W4 : NONE USED
z S/W5~S/W8 : CCU-310EV ID setting
- S/W5 (BIT3), S/W6 (BIT2), S/W7 (BIT1), S/W8 (BIT0)
- LOBBY MODE: ID1 ~ ID9 can be set.
Ex.) 10 LOBBY is set per one CCU-310EV. (Total of 90 units)
- DIP switch ID setting method : refer to “5-3-1. DIP switch setting method”.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Commax CCU-310EV and is the answer not in the manual?

Commax CCU-310EV Specifications

General IconGeneral
Model Name Spec.CCU-310EV
Wiring481 DATA : 2 lines (Polarity) / E/V connection : 2 lines (Non-polarity) RS-485 : 3 lines (Polarity)
Distance1Km (Pie 0.65 wire basis)
VoltageDC 12V / 1A
Power ConsumptionStandby : 55mA / Operation : 70mA
Operating Temp.0~+40℃