21
6-3. How to Set delay time of elevator call.
z Delay time can be set to prevent duplicate calls from different households when calling
elevator.( Default latency : 5sec)
The LED position moves when you press ID SET button.
(The delay time can be set in 8 steps, and the setting status can be checked by the
position where the LED is lit). (LED position and setting value: Refer to the wiring diagram)
Press the ID SET button for 3 seconds.
After the LEDs flash sequentially, the LED at the previously set position blinks.
The delay time can be changed to 5/10/20/30/50/90/180/300 seconds.
When the delay time is set, press the ID SET button again for 3 seconds.
All LEDs blink sequentially, and the LED changes to the operating state.
If there is no input for 30 seconds during setup, it will exit after saving the last setup.
Ι In case main entrance is open by RF card.
Î EL is automatically called to the floor in the which the lobby phone is located.
(LED of the port is turned on.)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Commax CCU-310EV and is the answer not in the manual?

Commax CCU-310EV Specifications

General IconGeneral
Model Name Spec.CCU-310EV
Wiring481 DATA : 2 lines (Polarity) / E/V connection : 2 lines (Non-polarity) RS-485 : 3 lines (Polarity)
Distance1Km (Pie 0.65 wire basis)
VoltageDC 12V / 1A
Power ConsumptionStandby : 55mA / Operation : 70mA
Operating Temp.0~+40℃