6-3. How to Set delay time of elevator call.
z Delay time can be set to prevent duplicate calls from different households when calling
elevator.( Default latency : 5sec)
The LED position moves when you press ID SET button.
(The delay time can be set in 8 steps, and the setting status can be checked by the
position where the LED is lit). (LED position and setting value: Refer to the wiring diagram)
Press the ID SET button for 3 seconds.
After the LEDs flash sequentially, the LED at the previously set position blinks.
The delay time can be changed to 5/10/20/30/50/90/180/300 seconds.
When the delay time is set, press the ID SET button again for 3 seconds.
All LEDs blink sequentially, and the LED changes to the operating state.
If there is no input for 30 seconds during setup, it will exit after saving the last setup.
Ι In case main entrance is open by RF card.
Î EL is automatically called to the floor in the which the lobby phone is located.
(LED of the port is turned on.)