Thank you for purchasing COMMAX products.
Please carefully read this Users Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Tel.
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Home Automation CDP-1020ID
User Manual
Question and Answer IconNeed help?

Do you have a question about the Commax CDP-1020IB and is the answer not in the manual?

Summary

1. Greeting

2. Warnings and Caution

3. Parts and Functions

4. Compositions

5. Main Menu

6. Household Setting

7. Away Mode Setting

8. Individual Door Talk

9. Guard Station Talk

10. Emergency Function

11. Telephone Function

12. Volume Control

13. EMS Function (Device Control)

16. Guard Security Function

17. Wiring

Diagram

Visual representation of wiring connections for the CDP-1020ID unit.

Wiring Method

Guidelines and precautions for connecting wires correctly to the device.

18. Operation Tips

19. Attention When in Use

20. Miscellaneous

Getting Help

Procedures for contacting support and when to seek professional service.

To Service The Unit

Contact information for customer service for unit servicing.

21. Specifications

Overview

This document describes the COMMAX CDP-1020ID Home Automation Videophone, a multifunctional device designed for apartments, villas, and other buildings, offering door opening, telephone conversation, and guard station control functions.

Function Description

The CDP-1020ID serves as a central hub for home automation and security. Its primary functions include:

  • Door Camera Monitoring and Talk: Allows users to view and communicate with visitors at the individual door camera.
  • Guard Station Call and Talk: Facilitates communication with the building's guard station.
  • Telephone Function: Supports telephone, extension, and neighbor talk.
  • EMS (Energy Management System): Provides remote control capabilities for Secumax (remote metering and control) and device control for lighting, gas valve, and boiler systems.
  • Security Functions: Includes settings for Security1 (Burglar1 - magnetic sensor) and Security2 (Burglar2 - PIR sensor), as well as emergency functions.
  • Delivery Notice: Allows users to check delivery notices from the guard station.
  • Away Mode Setting: Configures the device for when residents are away, activating security sensors, turning off lights, closing gas valves, and blocking standby power.
  • Household Settings: Manages household number, PIN, and extension settings.
  • Volume Control: Adjusts receiving, calling, and button tone volumes for various functions like lobby, telephone, guard, individual door, neighbor, call sound, extension, and touch/ring tone.

Important Technical Specifications

  • Display: 25.65Cm (10.1") COLOR TFT-LCD (DIGITAL)
  • Power Source: 14V, 1.8A
  • Communication: HANDS FREE
  • Wiring:
    • Telephone: 2 wires
    • Door camera: 4 wires
    • Fire ladder: 2 wires
    • Lobby: 4 wires in common
    • Guard station: 8 wires in common
    • SLAVE: 6 wires
    • Emergency switch: 2 wires
    • Sensor: 12 wires
  • Call Sound:
    • Telephone: Ringer
    • Door camera: Chime (3 melodies, 2 times)
    • Guard station: Melody
  • Distance:
    • Door camera: 28m (Ø0.5)
    • Guard station: 1Km (Ø0.5)
    • Lobby panel: 300m (Coaxial cable)
  • Channel:
    • Guard station: 3 channels
    • Lobby panel: 1 channel

Usage Features

General Operation:

  • Hands-Free Conversation: Initiate or end calls by pressing the talk button.
  • Master Unit: The product is designated as a Master unit and can connect to multiple Slave units.
  • Call Overtake: If one video-phone terminal is busy, another terminal can overtake the call.
  • Emergency Notifications: In case of emergency (fire, gas, burglar), notifications are directed to all installed devices, and conversation through the videophone is forcibly terminated.

Household Setting:

  • Household No. Setting: Enter building and room numbers for identification.
  • PIN Setting: Set a 4-digit PIN for security.
  • Extension No. Setting: Configure extension numbers (2-9) for sub-phones to call the guard station.

Away Mode Setting:

  • Activation: Activate security sensors (Security1, Security2), turn off all lights, close gas valves, and block standby power.
  • Delay Time: Set a delay time (0-90 seconds) for security sensors to activate after away mode is enabled (default 60 seconds).
  • Releasing Delay Time: Set a delay time for reactivating sensors when returning home (default 0 seconds), which triggers an alarm if exceeded.

Individual Door Talk:

  • Monitoring: View the door camera feed.
  • Communication: Talk with visitors.
  • Door Release: Open the door while talking with a visitor.
  • Volume Control: Adjust receiving and call sound volumes.
  • Display Settings: Adjust color, contrast, and brightness.
  • Screen Scrolling and Zoom: Zoom in/out and drag the screen view (PTZ function available only with PTZ-enabled door cameras).

Guard Station Talk:

  • Calling: Initiate a call to the guard station.
  • Receiving Calls: Communicate with the guard station when a call is received.
  • Volume Control: Adjust receiving sound volume.

Emergency Function:

  • Activation: Press the Emergency button for more than 1 second to generate an emergency signal to the guard station with an audible alarm.
  • Release: Press the "Release" icon to stop the signal.
  • Return to Standby: Press the "Return" icon to go back to standby status after an emergency is released.

Telephone Function (Telephone/Extension/Neighbor Talk):

  • Number Registration: Register numbers for telephone, extension, and neighbor calls.
  • Making Calls: Dial numbers to call.
  • Receiving Calls: Talk when a call is received.
  • Call History: View recent call history (up to 5 calls).
  • ARS Service: Use the dial pad for ARS services.
  • Call Switching: Switch calls between different sources (individual door, lobby, guard, neighbor, extension, telephone).

EMS Function (Device Control):

  • Lighting Control: Turn lights on/off individually or all at once.
  • Gas Control: Open/close gas valves individually or all at once.
  • Boiler Control: View current and desired room temperatures, and set the desired temperature.
  • Remote Metering: Check real-time water, gas, electricity, hot water, and heat usage.

Detoured Call:

  • When away mode is activated, all calls from the lobby and individual door are detoured to the guard station.

Guard Security Function:

  • Alarm 1 (Fire): Activates a fire alarm signal to the guard station.
  • Alarm 2 (Gas): Activates a gas alarm signal to the guard station.
  • Fire Ladder Alarm: Sounds an alarm when the fire ladder is in use.
  • Security 1 & 2 (Burglar Sensor): Activates burglar alarms (police car sound) and sends signals to the guard station upon movement detection.
  • Release Security: Deactivate security settings.
  • Return Security: Return to normal security function after an alarm.

Maintenance Features

Warnings and Cautions:

  • Power & Installation:
    • Avoid using multiple products on one power socket to prevent overheating and fire.
    • Do not bend power cables excessively or use damaged cables to prevent electric shock and fire.
    • Do not handle power cables with wet hands to prevent electric shock.
    • Unplug the power cable when not in use for a long period to prolong product lifespan and prevent fire.
    • Avoid installing in oily, smoky, humid places to prevent electric shock or fire.
    • Avoid installing during lightning and thunder to prevent electric shock or fire.
    • Do not connect with products of different rated voltages to prevent disorder or fire.
    • Install at least 10cm away from walls for ventilation to prevent fire due to increased internal temperature.
  • Cleaning & Use:
    • Do not disassemble, repair, or rebuild the product arbitrarily to prevent electric shock or fire. Contact a service center for repairs.
    • If abnormal sound, burning smell, or smoke occurs, unplug the power cable and contact a service center.
    • Do not insert metallic or burnable materials into ventilation holes to prevent electric shock or fire.
    • Use only designated batteries for DC-powered products to prevent electric shock or fire.
    • Plug the power cable firmly into the inner end to prevent fire.
    • Hold the plug tightly when unplugging the power cable to prevent damage to copper wires, which can cause electric shock or fire.
    • Install the product with power off when connecting power cables after cutting them to prevent electric shock or fire.
    • Fix the product firmly using the wall-mounting unit and screws during installation to prevent injury from falling objects.
    • Be careful when using an AC circuit breaker due to the possibility of electric shock.
    • Check the use voltage and current for DC-only products and use the appropriate rectifier to prevent fire.
    • Avoid direct sunlight or heating devices during installation to prevent fire.
    • Do not install on unstable places or small support boards to prevent injury if it falls.
    • Clean with a soft, dry cloth after unplugging the power cable. Do not use chemical products like wax, benzene, alcohol, or cleanser.
    • Do not drop the product or apply shock to prevent failure.
    • Use the designated connection cable within the maximum calling distance to maintain product performance.

Troubleshooting Guide:

  • Blackened visitor image in clear background: Replace the camera to a place without backlight.
  • Blurry screen: Remove foreign substance from the lens.
  • No call to guard station/common lobby (DATA LINE out-of-order(2)): Problem in communication line; call A/S center.
  • Hung up automatically while talking: End talk within the preset time (1 min for individual entrance, 1 min for common entrance).
  • DATA LINE out-of-order(1): Call A/S center.

General Maintenance:

  • Installation: Do not install the product in different places if it uses common wiring.
  • Switch: Ensure the device switch is up.
  • Disassembly: Never disassemble or remodel the product. Consult dealership or customer service for repairs.
  • Objects on Product: Do not place metal objects, pots, or bottles on the product.
  • Fire Alarm: Use a proper disconnection device for interior wiring. Promptly shut down the disconnection device during a fire emergency.
  • Power Off: Turn off the device power when installing or repairing.
  • Calling Service Man: Read the User's Guide carefully before calling service. Check the entire checklist.
  • Before You Call: If problems persist, pull the power plug, wait 10 minutes, and plug it back in.
  • Getting Help: If operating problems cannot be corrected, contact your dealer or Commax Customer Service. Do not open the cabinet to avoid voiding the warranty.
  • Qualified Service Personnel: Unplug the unit and refer servicing to qualified personnel if the power supply/plug is damaged, the unit has been exposed to rain/water, a solid object/liquid has fallen into the unit, the unit exhibits a distinct change in performance, or the unit has been dropped/damaged.
  • Maintaining Your Unit: Occasional dusting is sufficient. Do not spray liquids on the unit.
  • Service: Customer Service can be reached at 1-080-902-2222.
  • Replacement Parts: Ensure service technicians use manufacturer-specified or equivalent replacement parts to prevent fire, electrical shock, or other hazards.

Commax CDP-1020IB Specifications

General IconGeneral
BrandCommax
ModelCDP-1020IB
CategoryHome Automation