Refer to C4000 Set-Up K Factor Switch Settings (see page 21) While
setting the Product density factor, the price display shows 'dSF' („dFb‟ for
side “B”) and the volume display shows 'X.XXXX'.
Specific Density (With a densometer)
This setting is only available for LPG dispensers with a densometer and
set-up for LPG with temperature compensation (configuration code =
7xx5x). This is not available in other modes.
For Bulkmeter modes (Sr=0) and LPG dispensers with
temperature compensation but without a densometer (configuration code =
5xx5x), the density must be set at the dispenser.
The specific density of the LPG is measured to allow the C4000 to
accurately convert the amount of LPG dispensed to the LPG dispensed @
15ºC. The specific density of the product is measured using the Compac
densometer and is corrected to specific density at 15ºC. It is always
displayed in units of kg/m3.