3. Safety regulations
12
3.7 General workplace dangers
Danger
Safety measure required
This manual only describes how to work
safely with the compressor itself. But
other dangers will arise during work.
Please note and pass on general statutory and other binding regulations that
may supplement the operating manual for the prevention of accidents and the
protection of the environment. Such obligations may be for example the
handling of hazardous materials, or the provision and/or wearing of personal
protective equipment, or traffic regulations.
Instructions, including supervisory responsibility and duty of notification for
taking account of special in-plant factors, for example regarding work
organization, sequences of operations, personnel assigned to certain tasks,
are to be added to the operating manual.
Before starting work, make yourself familiar with the working environment at
the installation site.
The location and operation of fire extinguishers must be made known.
Observe the instructions concerning fire alarm and fire fighting.
Set up the machine in such a way that no inlets, outlets or gates are blocked.
When handling chemical substances observe the safety regulations
applicable for the product.
Caution when handling process materials (risk of burning / scalding).
3.8 Dangers resulting from neglecting to perform maintenance
Danger
Safety measure required
Components of importance to safety
wear over time.
Observe the setting, maintenance, and inspection work and intervals
stipulated in the operating manual, including information about the
replacement of parts / partial sections. This work may only be carried out by
specialists.
Observe the intervals stipulated or those given in the operating manual for
routine checks and inspections.
Verify regularly that safety valves and other pressure-relief devices are in
perfect condition and are not blocked, for example by dirt or paint
Check regularly that the safety mechanisms are fully functional. Have
malfunctions corrected immediately.
Lines perish.
Check regularly that all hoses and/or pipes within the system are in good
condition, firmly fixed and do not chafe.
Replace hydraulic hose lines at the stated or at reasonable intervals even if
no defects of relevance to safety are apparent!
Spurting oil can result in injuries.
Check all lines, hoses, and bolted connections regularly for leaks and visible
damage. Repair damage immediately and always arrange for damaged parts
to be replaced!

Table of Contents

Other manuals for CompAir L18

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir L18 and is the answer not in the manual?

CompAir L18 Specifications

General IconGeneral
BrandCompAir
ModelL18
CategoryAir Compressor
LanguageEnglish

Related product manuals