8. Storage of compressors
38
8 Storage of compressors
8.1 Shutdown
All compressors are protected against corrosion at the
factory for transport and for brief storage before
commissioning.
If the compressors are to be stored for period
exceeding six months, additional precautions must be
taken.
Compressors which are to be shut down for a lengthy
period must also be protected from corrosion.
Since corrosion occurs more quickly in damp
atmospheres than in dry conditions, it is not possible to
specify a maximum permissible standstill time which will
apply in all cases.
Note
The following aspects must be taken into account for
storage of storing compressors.
The compressor should be stored in a dry building
which should be heated if possible. This is particularly
true during the months of winter.
The coolant is to be completely drained where there is
a risk of frost (t < 1°C) (compressor stage, coolers,
system containers, water filters, storage containers,
RO unit, lines, valves).
If there is a risk that the temperature will fall or rise
above the limits of -10 °C (14 °F) to +65 °C (149 °F) ,
the electrical controller must be removed and stored in
ambient temperatures of +5 °C (41 °F) to +30 °C
(86 °F).

Table of Contents

Other manuals for CompAir L22

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CompAir L22 and is the answer not in the manual?

CompAir L22 Specifications

General IconGeneral
ModelL22
CategoryAir Compressor
Motor Power22 kW
Motor Power (hp)30 hp
Noise Level67 dB(A)
Weight520 kg

Related product manuals