CompAir Limited
page 16
LEADING PARTICULARS
Note: There are detail differences depending on the compressor concerned. The designations are as follows:
Basic
V100 VL200
Low pressure model prefix:
L V
L
200
designation:
V150 VL300
Oil-free model suffix:
D V200
D
V200 VL400
Air-cooled suffix:
A VL300D
A
V300
Water-cooled suffix:
W V100
W
Motor rating suffix:
F2 or F3 V100DW-
F3
In the tables below the models are identified by the appropriate prefix or suffix.
Ambient Temperature:
Running speed:
Working pressure:
V-F2 VL200A-F2 VL200DA-F2 V300DA-F3 All other
VL300A-F2 VL300DA-F2 only V-F3
VL400A-F2 VL400DA-F2 models
7 bar 3.5 bar 2.4 bar 8.6 bar 10.3 bar
V150/V300 VL200/VL400 VL300
222.3 mm 196.9 mm 222.3 mm
133.4 mm - -
98.4 mm 85.5 mm 98.4 mm
Piston stroke:
V100/V200
196.9 mm
114.3 mm
85.5 mm
Cylinder bore:
2nd stage:
4.1 bar
Working pressure:
maximum:
Motor rotation:
Clockwise, viewed from motor end.
1st stage:
normal :
maximum:
All Models:
1.4 barminimum:
V VL
All Models:
1,460 rev/min
1 ,500 rev/min
VL
0°C
50°C
minimum:
maximum:
V
0°C
55°C
VL
1-Stage, single acting
W
Water-cooled
V
2-Stage, single acting
A
Air-cooled
Model:
Type:
Model:
Intercooler: