B-012
The configuration setup page reports all the possible selectable choices. To print configuration
setup page see the Printer Setup section of this manual.
Setup parameter Values Description
MSRW STANDARD IBM3604 Magnetic stripe standard selection
DIN32744
ANSI
BURR. 1
BURR. 2
END SENTINEL F End sentinel symbol, valid only for IBM3604
C
DISPLACEMENT STANDARD
+10
+20
Allows to select the displacement of the
magnetic stripe
DUPLICATE NO
YES
Field duplicate attribute. When ON, data are
recorded in duplicated way
DBL FIELD CHECK NO
YES
When YES check is done to verify the same
information on duplicated fields.
MSRW RETRY 1 Number of retries before operation failure.
2
3