Loading...
can be modified so that the display alternately shows the
current room temperature and the adjusted temperature for 4
seconds, respectively. In this mode, notices ROOMand SET
are alternately shown under the currently displayed temperature
in the bottom right corner of the display, indicating whether the
display shows the room temperature or the adjusted temperature
value.
Attention! To modify the factory default settings after inserting
the batteries, press the “Reset” button with a small wooden or
plastic stick to activate them.
3.4 Synchronising the Thermostat and the Receiver Unit
In order to have a safe, reliable
and trouble-free wireless (radio-
frequency) connection, both the
thermostat and the receiver unit
have their own safety codes. After
installing the receiver unit, the
two units should be synchronised
by pressing the LEARN button
next to the battery compartment of
the thermostat. Therefore do not
replace the rear panel of the thermostat onto the front panel before
synchronisation. The process of synchronisation is described in
Section 7.2.
4. SETTING THE DESIRED TEMPERATURE
The factory default temperature was set to 20°C and in case of
the default switching sensitivity 0.2°C), the thermostat switches
on and off the connected heating appliance below 19.8°C and
above 20.2°C, respectively. This default temperature can be freely
changed in steps of 0.5°C between 10°C and 30°C as follows:
Press the or button and the notice „• SET” (adjusted
- 6 -