7 Tr o u b le s h o o t in g
ENGLISH
Meaning of the LED indicators
Ready Solar Gen-
erator
Grid
Fault Meaning
Reversible temporary fault (e. g. grid
failure, excess temperature).
Diagnostic information, e. g.
temperature warning, power feed to
the grid during output reduction
Grid fault, inverter is in stand-by
mode
The inverter waits 2 minutes before
switching back on after a grid failure.
Connection: audible clicking of the
relay
Internal electronics systems will not
be supplied due to insufficient solar
generator voltage.
Inverter is not supplying power.
Insulation fault, e.g. earth leakage
Internal fault:
The inverter switches off. If the fault
arises again the next day, it switches
itself off again. The inverter notes
that it is a critical fault and remains
switched off permanently.
Please contact Conergy Service.
LED is illuminated
LED is flashing
(LED lights up regularly)
LED is flashing
(brief illumination of the LED every 2 seconds)