EasyManua.ls Logo

Conrad Electronic I-180 - Model I-380; Model I-580 X

Conrad Electronic I-180
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
When using the timer function, the fog burst always lasts 3 seconds; you can set
the break between the fog bursts from 5 to 200 seconds with the interval con-
troller.
Extending the break time Turn the controller clockwise
Reduce the break time Turn the controller counterclockwise:
Model I-380
This model has a manual and a timer function and can also be controlled via an
external DMX controller (see next chapter).
As soon as the device is turned on, the display POWER (red) and READY (green)
blink.
Once the heating phase is finished, the displays POWER (red) and READY (green)
stay lit.
Press the green fog button on the remote control to trigger the fog function man-
ually. This button always triggers the fog output, even when the timer function is
deactivated.
Turn the interval controller to the right to turn on the timer function. The yellow dis-
play lights up as soon as the timer function is activated.
When using the timer function, the fog burst always lasts 3 seconds; you can set
the break between the fog bursts from 5 to 200 seconds with the interval con-
troller.
Extending the break time Turn the controller clockwise
Reduce the break time Turn the controller counterclockwise:
As long as the device re-heats, the displays POWER (red), READY (green) and,
insamuch as active, the display TIMER (yellow) blink.
Model I-580X
With this model, you can set the fog duration, the break duration between fog bursts
and the fog output.
The red display is lit as soon as the device is turned on.
Once the heat-up phase is complete, the green display is lit additionally and the
device is ready for fogging.
Press the green fog button MANUAL on the remote control to trigger the fog func-
tion manually. This button always triggers the fog output, even when the timer
function is deactivated. In addition, this function always puts out the maximum
fog quantity.
Press the yellow button TIMER to activate the timer function.
With the controller INTERVAL, set the break time between the fog bursts (range
from 10 seconds to 5 minutes).
With the controller DURATION, set the duration of each fog burst (range 1-10 sec-
onds).
Press the red button CONTINUOUS to trigger continuous fog operation.
Control the fog output with the controller OUTPUT.

Table of Contents