Edition 05/2021 CC200 D Notice technique page 4
SACOME, Document CONFIDENTIEL, Ne peut être reproduit ni communiqué sans notre accord préalable.
4. INSTALLATION
4.1. IN CASE OF A STANDBY OF THE MACHINE (STANDBY = 2 MONTHS):
The first thing to do is to test your machine in a lab.
If the machine stop ruming for a long time, you could have scale in some places.
More precisely in small area like the spray nozzle.
4.2. PROTECTIONS
It is necessary to place before the machine:
o A water shutoff valve.
o An electrical protection standard, suitable for voltage and power consumption.
4.3. WATER SUPPLY
Recommended operating pressure from 0,15 MPa to 0,6 MPa
Water connection pin 3/8"
The water supply pipes must resist to 145 Psi / 1 MPa
4.4. DRAIN
Without pressure.
Spigot at the outlet of the machine and a pipe is supplied with the machine
Ensure a connection that causes no risk of fluid return, and ensure good drainage:
The drain pipe must be located lower than the machine.
Do not create a bend in the exhaust tube.
4.5. SUPPLYING VOLTAGE
According to the model:
230V 50/60Hz Monofase
400V 50/60Hz Trifase