EasyManua.ls Logo

Conti X-one User Manual

Conti X-one
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
- Edition 05/2014
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
SOFT VERS. 1.04 & SC 1.03
TECHNICAL DOCUMENTS
Question and Answer IconNeed help?

Do you have a question about the Conti X-one and is the answer not in the manual?

Conti X-one Specifications

General IconGeneral
BrandConti
ModelX-one
CategoryCoffee Maker
LanguageEnglish

Summary

TECHNICAL DOCUMENTS

DIMENSIONS

Provides detailed measurements and diagrams of the machine, including weight and boiler capacity.

CAUTION DURING THE USE

AMBIENT CONDITIONS

Specifies required temperature and humidity ranges for machine operation.

DURING INSTALLATION

Outlines essential installation requirements and safety precautions for qualified technicians.

DURING THE USE

Provides guidelines for safe operation, including water cutoff and power disconnection.

RULES RELATING TO THE ENVIRONMENT

Details environmental compliance and disposal instructions according to European directives.

INSTALLATION

IN CASE OF A STANDBY OF THE MACHINE (STANDBY = 2 MONTHS)

Instructions for machine standby and potential issues like scale formation.

PROTECTIONS

Lists necessary protective measures and components like water shutoff valve and electrical protection.

WATER SUPPLY

Specifies requirements for water pressure and connection types for the machine.

DRAIN

Details requirements for proper drainage system setup, ensuring no fluid return.

SUPPLYING VOLTAGE

Specifies available voltage options (230V Monofase, 400V Trifase) for machine operation.

WATER SOFTENERS

What is the total Hardness of the water?

Explains water hardness measurement and units (°TH or °dH).

What is the Karbonat Hardness of the water?

Explains carbonate hardness measurement using °Carbonate (°KH).

There are 2 types of water treatments:

Describes salt water softeners and resin filters for water treatment.

OPERATION

RECOMMANDATIONS

Initial recommendations before powering on and filling the machine.

INITIAL FILLING

Step-by-step guide for the initial filling and heating of the machine.

FURTHER FILLINGS

Explains automatic water level management in the boiler.

HOW TO USE THE MACHINE

OPERATING ELEMENTS

Explains the function of steam taps, hot water tap, and filter holders.

FILTERS

Information on filter types (1 cup, 2 cups) and cleaning procedures.

FILTER-HOLDER

Proper handling, engagement, and cleaning of the filter-holder.

MANOMETER M1: BOILER PRESSURE

Explains the boiler pressure gauge and factory settings.

MANOMETER M2: PUMP PRESSURE

Explains the pump pressure gauge and its function during extraction.

HOW TO USE THE PROGRAMMED DOSES

Instructions for selecting and using pre-programmed coffee doses via keypad.

PROGRAMMING METHODOLOGY

NORMAL MODE or ECO MODE

Explains the machine's normal operating mode and energy-saving ECO mode.

TWO PROGRAMMING LEVEL

Details the two available programming menus: BAR and TECHNICAL.

COFFEE DOSES PROGRAMMING

Step-by-step guide for programming coffee doses for single or multiple groups.

HOT WATER DOSE PROGRAMMING

Instructions for programming hot water dispensing amounts for X-One and X-One TCI.

AUTOMATIC CLEANNING OF COFFEE GROUP

Procedure for automatic cleaning of coffee groups using detergent tablets.

ECONOMIC MODE

Explains the machine's energy-saving standby mode and its benefits.

BAR MENU PROGRAMMING PARAMETERS

BAR MENU

Overview and entry into the BAR menu for programming settings.

Clock Adjust

How to set and adjust the machine's internal clock time and day.

Automatic on/off mode

How to program automatic power on/off times for the machine.

Day off setting (Closed on)

How to set days when automatic switching is disabled.

Counters

Explains the types of counters available and how to access and read them.

Counters reset

Procedure for resetting specific machine usage counters.

TECHNICAL MENU PROGRAMMING

TECHNICAL MENU

Overview of how to access and navigate the technical menu for advanced settings.

Temperature

Options for setting boiler temperature in Celsius or Fahrenheit units.

Steam boiler temperature adjustment

Allows you to define the setting temperature in the steam boiler.

PID adjustment range

Fine-tune PID system parameters for improved temperature stability.

Compulsory groups cleaning programming

Program mandatory cleaning times for coffee groups to ensure machine upkeep.

ALARM MESSAGES AND SOLUTIONS

Cleaning alarm

Explains compulsory and warning cleaning alarms and their resolution.

Filling up time out

Identifies reasons and solutions for filling timeout alarms.

Boiler temperature alarm message

Describes boiler over-temperature alarms and reset conditions.

The machine does not turn on

Lists possible reasons and solutions when the machine fails to power on.

SUMMARY OF PROCEDURE FOR RESETTING THE COUNTERS

RESETTING THE COFFEE COUNTER

Procedure to reset the coffee usage counters.

RESETTING THE "MAINTENANCE" COUNTER

Procedure to clear the maintenance reminder message.

RESETTING THE « FILTER » COUNTER

Procedure to reset the filter usage counter.

TROUBLESHOOTING FACILITATORS

STOPPING TAPS

Describes isolation taps located below the drip tray for troubleshooting.

DATA RESET

Procedure to reset machine settings to factory defaults.

COLD CONDITIONS FUNCTIONNING

Information on machine operation in cold conditions (UNDER CONSTRUCTION).

METHOD OF ADJUSTING COFFEE TEMPERATURE ON X-ONE MODEL

AJUSTEMENT DE LA TEMPERATURE CAFE

How to adjust coffee temperature by acting on the steam boiler.

THERMOSIPHONIC BALANCE

How to adjust coffee temperature using the break screw for stability.

METHOD OF ADJUSTING COFFEE TEMPERATURE ON X-ONE TCI MODELS

STEAM BOILER TEMPERATURE ADJUSTMENT

Adjusts steam boiler temperature for TCI models based on steam needs.

COFFEE TEMPERATURE ADJUSTMENT

How to adjust coffee temperature via the mixer on TCI models.

THERMOSIPHONIC BALANCE

How to adjust coffee temperature using the break on TCI models for stability.

HOW TO MAKE THE PERFECT COFFEE

The Mix

Importance of coffee bean type (Arabica vs. Robusta) and roasting for quality.

The Grinder

Details on grinder capacity and grind adjustment for optimal coffee.

The Machine

Requirements for machine adjustment, cleanliness, and maintenance for quality.

The Hand

Operator skills for maintaining coffee quality and machine care.

The Maintenance

Importance of daily cleaning for coffee quality and machine operation.

MAINTENANCE OF MACHINES

DAILY MAINTENANCE

Steps for daily cleaning of various machine parts like outlets and drip tray.

HALF YEAR MAINTENANCE

Procedures for semi-annual maintenance tasks, often involving kits.

ANNUAL MAINTENANCE

Procedures for annual maintenance tasks and part replacements.

ENTRETIEN BIENNAL

Procedures for biennial maintenance tasks and part replacements.

ELECTRONIC DIAGRAM STANDARD VERSION

DESIGNATION OF USEFUL CODES

Lists and defines codes used in electronic diagrams for components.

CODE COULEURS FILS CABLE COLOUR CODE

Provides a color code key for electrical wires used in the diagrams.

ELECTRICAL HEATING CIRCUIT FOR X-ONE 2G 230V 3500W

Electrical schematic for a specific machine configuration (2G 230V).

ELECTRICAL HEATING CIRCUIT FOR X-ONE 3G 230V 6000W

Electrical schematic for a specific machine configuration (3G 230V).

ELECTRICAL HEATING CIRCUIT FOR X-ONE 3G 400V 6000W

Electrical schematic for a specific machine configuration (3G 400V).

ELECTRICAL HEATING CIRCUIT FOR X-ONE 2/3G 230V 3L PE 6000W

Electrical schematic for a specific machine configuration (2/3G 230V).

ELECTRICAL POWER CIRCUIT FOR X-ONE (STEAM CONTROL VERSION)

Electrical schematic for the steam control version of the machine.

HYDRAULIC SCHEMA

HYDRAULIC SCHEMA

Diagram illustrating the machine's hydraulic system components and connections.

OPTION AVAILABLE

SOLO KIT

Information about the SOLO KIT for using separate water tanks.

Related product manuals