Edition 05/2014 - X-ONE - page 35
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
ENTRETIEN BIENNAL:
- A kit n° 480331, for the following operation is available for sale.
- Change the pump inlet filter (No. 411861)
- On the boiler:
o Change vaccum valve (No. 408898)
o Change the safety valve (No. 404326)
- On the inlet bloc valves:
o Change the filter (No. 470199)
o Replace the gasket (No. 219100) of 2 non-return valves
o Remove and clean the gasket limiter 12 Bars
o Change the inlet boiler valve (No. 470161) + 2 PTFE gasket (No. 407500)
o Change the small solenoid "mixer" (No. 411374)
- On the coffee group
o Remove all the parts and uncork all the holes in the group head.
o Change the O-ring nozzle (No. 403457) and the filter nozzle (No. 403458)
o Change the 2 O-rings (No. 403457) of the braker
o Change the O-ring (No. 067100) on the breaker
o Change the solenoid coffee (No. 407329) + 2 PTFE gasket (No. 407500)
- On the electrical tap
o Change the solenoid "hot water" (No. 470161)
o Change the 2 PTFE gasket (No. 407500)
o Change the O-ring of the adjusting screw (No. 400 039)
- On the 2 steam taps:
o Change the 2 O-rings (No. 403457)
o Change the 1 gasket (No. 407502)
- On the 2 "steam" output and on the "hot water" output
o Change the O-ring (No. 061200)
o Change the O-ring (No. 055300)
o Change the washer (No. 401320)
o Change the O-ring of steam nozzles (No. 055400)
- For versions TCI: in the mixer:
o Change the O-ring (No. 087520)
- Change the silicone tubes evacuation 3-way valves cafes (No. 405621)