EasyManua.ls Logo

Conti X-one - ANNUAL MAINTENANCE

Conti X-one
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edition 05/2014 - X-ONE - page 34
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
ANNUAL MAINTENANCE:
- A kit n° 480331, for the following operation is available for sale.
- Change the pump inlet filter (No. 411861)
- On the boiler:
o Change vaccum valve (No. 408898)
o Change the safety valve (No. 404326)
- On the inlet bloc valves:
o Change the filter (No. 470199)
o Replace the gasket (No. 219100) of 2 non-return valves
o Remove and clean the gasket limiter 12 Bars
o Clean the nucleus of the solenoid inlet water boiler
o Clean the nucleus of the small solenoid "mixer"
- On the coffee group
o Change the O-ring nozzle (No. 403457) and the filter nozzle (No. 403458)
o Change the 2 O-rings (No. 403457) of the braker
o Change the O-ring (No. 067100) on the breaker
o Clean the 3rd way and the nucleus of the solenoid coffee valve
- On the electrical tap
o Clean the nucleus of the solenoid "hot water" valve
- On the 2 steam taps:
o Change the 2 O-rings (No. 403457)
o Change the 1 gasket (No. 407502)
- On the 2 "steam" output and on the "hot water" output
o Change the O-ring (No. 061200)
o Change the O-ring (No. 055300)
- For water quality issues, it is recommended to fully drain the boiler.