Level probe sensitivity:
According to the water hardness in the tanker, this allows you to adjust the sensitivity of the level probe.
The setting is made with + and – key.
Setting values: LOW, MIDDLE, HIGH
• LOW: softened water hurt
• MIDDLE: normal water
• HIGH: mountain water, or very pure water
Service cycles:
Allows to set the number of cycles (or coffee) that the machine can perform before a preventive maintenance
is required.
The setting is made with + and – key, with steps of 1000 cycles
Values are adjustable from 0000 (not management) to 99000
To reset, see chapter "Troubleshooting and Remedies - services»
Compulsory groups cleaning programming:
Allows you to program a requirement for a compulsory cleaning at a specific time.
If the group cleaning programmed is not done on all groups: machine is blocked.
The activation of compulsory cleaning function is made with + or - keys.
To set the time for the message « Groups cleaning » to be displayed press «Enter» and then press + or –.
Temperature unit choice:
Allows you to define the unit temperature °C or °F
All values are automatically converted when you change the unit.
Steam boiler temperature adjustment
Allows you to define the setting temperature in the steam boiler.
Adjustment range: 80 to 125 °C (176 °F … 257°F)
Resolution: 1°C
We advise 120°C for X-ONE,
123°C for X-ONE TCI.
To change temperature press + or – key.
To exit, press MENU, or wait 30 seconds.