Edition 05/2014 - X-ONE - page 21
SACOME, CONFIDENTIAL Document,
it is forbidden to duplicate or communicate this document without previous authorization.
Exposition mode :
If the exposition mode is « active », The machine is completely ON, but don’t react to any button, and don’t
control any heating. This status is shown by the word « EXPO » written on the display.
To come back to the normal mode:
Enter in the technical menu programming
Desactivate the exposition mode
Filling the boiler:
Allows to choose the filling mode of the steam boiler
- With pump (if the machine works with tank)
- Without pump (if the machine is connected on the network)
Dose programming access:
Allows you to leave or prevent access of the program doses.
The setting change is made with the + or -.keys.
Continual dose access:
Allows you to leave or prevent access of the continuous key.
The setting change is made with the + or -.keys.
Hot water distribution mode:
Allows you to choose if the hot water is distributed:
Only by opening the valve.
Or by activating the pump and the hot water valve.
This is the case when using a mixer
Steam control :
Setting parameters for the emulsion of 1 liter of milk foam on the X-TCI steam control.
Steam boiler T° 124 or 125 º c
Steam control target T° 70 º C
Milk qty in jug. 0.6 L
Standard air nozzle. yes
Pre Brewing setting:
Allows you to leave or prevent the use of the pre-brewing on each button. (to be define).
The setting (disable or enable) is made with the + or -.keys
You can set the pre-brewing time on the 4 different doses (those 4 setting will be the same on each group) by
pressing MENU. The displays will show:
Preinfusion time is in seconds.
First adjust all times On, then all times Off .
Product name = espresso – 2 espresso – coffee – 2 coffees.
To move forward press MENU
To exit, wait 30 seconds and do not press any button.
Prebrew On Sec