11 COFFEE TEMPERATURE ADJUSTMENTS
Factory adjustment:
Steam boiler temperature: 123°C
Coffee boiler temperature: 90°C
Group temperature: 90°C
On the one hand:
You choose the steam boiler temperature between 117°C (0.8 bars) and 125°C (1.4 bars).
On the other hand:
You choose coffee boiler temperature and group temperature to have the desire temperature.
To adjust the coffee temperature, you can change the coffee boiler and group temperature.
1°C on coffee boiler and group temperature -> 1°C on coffee temperature
Concerning the abacus above:
o These values are given in an indicative way, following the regulation and the especial
protocol of the CONTI Company.
o These can change according to the type of coffee used, as well as the environment of the
machine.
11.1.1 Hot water temperature adjustment
The factory setting is a hot water temperature at 92°C.
You can change this temperature by adjusting the screw above the tap.