Edition 05/2021 - MC ULTIMA- Technical documentation - page 65
SACOME, CONFIDENTIAL Document, it is forbidden to duplicate or communicate this document without previous authorization.
17 POWER MANAGEMENT
The Monte Carlo machines are three phase machines
When the machine is connected to a three-phase network, the absorbed power consumption does not need to be flanged.
In this case the Power Management is at its maximum position: 6.
The machine can be connected to a single phase 230V.
In this case:
1: Change the power cable with a cable 3x6 ² (Conti reference: 103600)
2: Depending on the available amperage on the grid (16A / 20A / 32A):
It is necessary to adjust the power consumption of the machine.
Through the Power management (see table below)
3: Here's how to connect the 3x6 ² cable on the general relay machine
Nota Bene:
It is possible to retain the original cable (5x2,5 ²), but in this case:
It is imperative to curb the power management 1 (or 2 maximum if the machine is not used too much)
Power parameters and Current comsumption (for 230 volts monophase)
Power 1/2/3/4/5/6:
That’s the number of heating element can be supplyied at the same time in the machine
The priority is always given to the coffee Boiler