Model 2424 800-621-941913
Code
Displayed
Fault Remedy
Air Supply or Exhaust Blockage
No Ignition
Flame Failure
Earthing Failure
Remaining Flame Safety Device
Over Temperature Warning
Heat Exchanger Incoming Water
Temperature Sensor Faulty
Outgoing Water Temperature Sensor Faulty
Mod. Solenoid Valve Answer Abnormal
Combustion Fan Failure
Solenoid Valve Driving Circuit Faulty
Flame Sensing Device Faulty
Scale build-up in Heat Exchanger
Check that nothing is block-
ing the air intake or exhaust.
Check that the gas is turned
on at the water heater, gas
meter or cylinder.
Check that the gas is turned
on at the water heater and gas
meter. Check for obstructions
in flue outlet.
Service Call
Service Call
Service Call
Service Call
Service Call
Service Call
Service Call
Service Call
10
11
12
14
16
31
32
52
61
71
72
LC
Service Call
ERROR MESSAGES
The Continuum 2424 has the ability to check its own operation continuously. If a fault occurs,
an Error Message will flash on the Digital Monitor of the Remote Controls. This assists with
diagnosing the fault, and may enable you to overcome a problem without a service call.
Please quote the code displayed when inquiring about service.