Model 2424www.rinnaiamerica.com 20
This manual must be followed exactly.
1) Read the safety issues completely before installing the Continuum 2424.
2) This water heater is suitable for water (potable) heating or space heating.
- The piping connected to the Continuum 2424 must be approved for use in
potable water systems.
- Toxic chemicals such as those used for boiler water treatment are NOT to be
introduced to the Continuum 2424.
- The Continuum 2424, if it will be used as a potable water source, it must not
be connected to a system that was previously used with a nonpotable water
heating appliance.
3) The Continuum 2424 is not suitable for use as a pool or spa heater.
4) The dip switches on the computer board have been preset at the factory and
should not be readjusted without the express knowledge and involvement of
Rinnai.
5) Install the Continuum 2424 outdoors only.
6) Maintain proper space around the unit for proper servicing and operation.
Minimum clearances from combustible materials are listed below.
Top of Heater 12 inches
Back of Heater 0 inch
Front of Heater 24 inches
Sides of Heater 6 inches
Ground 12 inches
DO NOT install the Continuum 2424 under an overhang less than 3 feet from
the top of the unit. The area under any overhang greater than 3 feet must be
open on three sides.
7) Installer must install a Pressure relief valve. Pipe pressure relief discharge to a
drain or outside environment (see page 27).
INSTALLER’S INSTALLATION INSTRUCTIONS
-Warnings-