EasyManuals Logo

Contour Next Link 2.4 Quick Reference Guide

Contour Next Link 2.4
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DATE:
CLIENT:
DESCRIPTION:
SCHAWK JOB#:
SKU#:
DIMENSIONS:
PRINTER SPEC:
RELEASE: V-1
LANGUAGE(S): ENGLISH
INTERNAL: R-X
18211 NE 68th Street, E120
Redmond, WA 98052
T: 425-881-5454
BAN#: 85696475 Rev. 03/17
Contour Next LINK 2.4 QRG WEB - US
Alt#1 - 03/07/17 Copy Changes
March 07, 2017
Ascensia Diabetes Care
Contour Next LINK 2.4 QRG WEB US -
English
922002
Multi Parent BAN#: 81914672
16.5” (H) x 8 (W)
10000752618 REV -
FONTS:
Arial, Helvetica, Helvetica Neue, Zapf Dingbats, Skinny Mini, Mini Micra, Myriad Pro
COLORS:
Cyan Magenta Yellow Black 281 Process Build: 100C 79M 10Y 42K
NOTE: THIS COLOR PROOF INDICATES COLOR BREAK ONLY AND MAY NOT ACCURATELY REFLECT ACTUAL PRODUCTION COLOR.
Regional Master Template No: N/A
Clinical Trial / Global Master Template No: N/A
®
Use the arrow
buttons to
scroll to Continue.
Press the Select
button .
CONNECT TO PUMP
?
OK
Go Back
Select “Connect
Device” on your Pump.
CONNECT TO PUMP CONNECT TO PUMP
Cancel
Searching...
Turn the page over to complete setup.
¬
QUICK REFERENCE GUIDE
120
mg
dL
Before Meal Before Meal
12:24 PM l 10/13
BolusBolus
ReminderReminder
NotesNotes
Uses only C
ONTOUR
®
N
EXT
Blood Glucose Test Strips
?
OK
Skip
Connect to a
MiniMed Pump?
CONNECT TO PUMP
New Device
See User Guide to connect
new device. Select Search
below when ready.
Search
* Wall charger may not be included in all meter kits. Contact Customer
Service for information on obtaining a wall charger.
120
mg/dL
BG
12:24
PM
Active Insulin 0.0 u
MiniMed
®
670G is shown
Initial Setup of Meter and Connection
to MiniMed
®
Insulin Pump
1
Remove the USB cap to reveal the USB
connector.
Charging Meter
2
To begin setup,
hold down the
topMenu button
for several
seconds until the
meter turns on.
Unplug Meter From Charging
Source Before Beginning Setup
Connect to Pump
3
Scroll down to select
your language.
Press OK.
5
Connect to a MiniMed Pump?
Press OK.
6
Press OK.
Put the meter down and
pick up your pump.
7a
Press any button to turn the
screen on.
Press the Menu button
.
If your pump does not have a
Menu button go to step 7b.
7b
Press the Select button
.
Use the Down arrow button
to scroll to Options.
Press Select button .
8
Press the Down arrow button
to scroll to Utilities.
Press Select button
.
Utilities
Self Test
Carb Unit
Manage Settings
Sensor Demo
Device Options
9
In the Device Options menu,
scroll to Connect Device.
Press the Select button .
Device Options
Manage Devices
Connect Device
10
Place the meter and pump next
to each other.
Select Auto Connect on your
pump.
11
Read the pump screen, using the down arrow to
scroll to the next page.
12
Place the meter and pump next
to each other.
Select Search on the pump.
Search
Cancel
CONNECT TO PUMP
Select “Search” on
your Pump and meter.
The search may take up
to2minutes.
13
Check to see if Device SN
(serial number) on the pump
matches the Device SN on
the meter.
If they match, scroll to
Confirm on the pump.
Press the Select button .
CONNECT TO PUMP CONNECT TO PUMP
Use Pump to confirm Device
SN:
BGJ133333F
Confirm Device SN
GTJ133333F found SN:
BGJ133333F
ConfirmCancel
14
Turn the pump over.
Make sure that the SN on the
back of the pump matches
the pump serial number now
on the meter screen.
Press Next.
?
Next
Delete
MiniMed Pump
connected:
AA1234567B
15
Select Always and press
OK on next screen.
Always
Ask Me
Never
Automatically send
results to the
Pump?
SEND OPTIONSSEND OPTIONS
16
Select the Date Format.
Month/Day/Year
Day.Month.Year
SELECT
DATE FORMAT
?
17
Press OK.
Note: If time and date
are incorrect, you must
change them on the
pump.
OKOK
Date / Time is
set by Pump.
DATE / TIME
?
18
Press Accept to select
AutoLog is Off.
AutoLog allows you to
mark a test result as
Fasting, Before Meal, or After Meal. See your user
guide to learn more.
Accept
Turn On
AutoLog is Off.
AUTOLOGAUTOLOG
?
Wireless Blood Glucose
Monitoring System
Connect Device
Manual Connect
Auto Connect
?
Manual Connect
Auto Connect
CONNECT TO PUMPCONNECT TO PUMP
4
Press OK if the correct language is displayed.
Press NO if the incorrect language is displayed.
If pump screen goes blank, press
any button to turn it back on.
When the pump links to the meter, the SN on
the meter screen will change to a different serial
number. This number is the pump SN.
PUMP CONNECTEDPUMP CONNECTED
Select Auto Connect on
your meter.
Select Search on the
meter.
10:30 AM | 10/13/11
are in search mode.
Auto Connect
Before using Auto
Connect, be sure no other
nearby MiniMed devices
Cancel
Continue
English
Deutsch
Español
LANGUAGE
OKOK
For the MiniMed 630G
For the MiniMed 670G
OR
In the Utilities menu, use the
down arrow to scroll to
Device Options.
Press the Select button .
85696475 Rev. 03/17
Enter BG
Basal
Audio Options
Status
Suspend Delivery
Options
Menu
Insulin Settings
Sensor Settings
Event Markers
Reminders
Utilities
BG
Active Insulin
Bolus Basal
1.5 u
mg/dL
12: 24
PM
BG
Active Insulin 0.0 u
mg/dL
12: 07
AM
USB Connector
Selection/Scrolling Buttons
Test Strip Port
Display Screen
Test Strip Port Light
Top Menu Button
Protective USB Cap
MiniMed
®
670GMiniMed
®
630G
Meter
p
,
e
t
on
th
e
n.
F
rom
C
har
g
in
g
B
e
g
innin
g
Se
Se
p
p
NOTE: Check the units of measure of your meter.
See your meter user guide for complete instructions.
The CONTOUR
®
NEXT LINK 2.4 meter has a
permanent rechargeable battery.
Charge your meter with the wall charger* or by
plugging the USB connector into a computer. Be
sure the computer is turned on.
Your meter will briefly display “Do Not Test–
Charging” and the test strip port light will flash. You
cannot do ablood glucose test while the battery
ischarging.
When charging is finished, the test strip port light
will turn off. Unplug your
CONTOUR NEXT LINK 2.4
meter totest.
Graph
85696475_CntrNextLINK2_4_QRG_EN_FpBp_WEB_v1 1 03/07/17 9:55 AM
Display
Screen
Menu
Select
Right
Right
Up
Back
Back
Left
Down
Notification Light
March 26, 2017

Other manuals for Contour Next Link 2.4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contour Next Link 2.4 and is the answer not in the manual?

Contour Next Link 2.4 Specifications

General IconGeneral
BrandContour
ModelNext Link 2.4
CategoryBlood Glucose Meter
LanguageEnglish

Related product manuals