EasyManua.ls Logo

Contour Next GEN 9658 - User Manual

Contour Next GEN 9658
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
10 45 412 22
93
USER GUIDE
Uses only Contour
®
next
blood glucose test strips.
Works with the
Contour
®
Diabetes app available for
download from the App Store
®
or on Google Play
TM
.
Blood Glucose
Monitoring System
Question and Answer IconNeed help?

Do you have a question about the Contour Next GEN 9658 and is the answer not in the manual?

Summary

Contour Next GEN Blood Glucose Meter User Guide

System Overview and Key Features

Introduces the Contour Next GEN meter, highlighting features like NO CODING and Second-Chance sampling.

Getting Started with Your Contour Next GEN

Customer Service and Kit Contents

Provides contact info for customer service and lists items included in the meter kit.

Intended Use of the Monitoring System

Details the purpose and scope of the blood glucose monitoring system.

Important Safety Information

General Safety Warnings and Precautions

Covers critical warnings regarding testing, biohazards, and hygiene practices.

Consulting Your Healthcare Professional

Advises on when and why to consult a healthcare provider for test results.

System Specifications and Limitations

Device Limitations and Serious Illness

Outlines limitations for specific patient conditions and system usage constraints.

Operating and Storage Environment

Specifies temperature and humidity ranges for meter and strip operation and storage.

System Precautions and Meter Features

Handling, Battery, and Usage Precautions

Details precautions for battery safety, device handling, and environmental exposure.

Meter Features and Specifications Overview

Describes meter features like 'Easy' and 'Automatic' operation, measuring range, etc.

Getting Started: Meter Operation

Your CONTOUR NEXT GEN Meter

An overview of the physical meter, including buttons and ports.

Navigating the Meter Interface

Explains how to use the meter's buttons for navigation and selection.

Understanding the Meter Display

Meter Screen Symbols Explained

Defines the meaning of various symbols displayed on the meter screen.

Preparing for Blood Glucose Testing

Using the CONTOUR NEXT Test Strip

Instructions on how to insert and use the test strip correctly in the meter.

Understanding Target Ranges

Explains how the meter compares results to set target ranges.

Blood Glucose Testing Procedures

Using Meal Markers

Guides on how to apply meal markers to test results for tracking.

Getting Ready to Test

Steps and checks to perform before starting a blood glucose test.

Performing a Blood Glucose Test

Fingertip Blood Sample Collection

Detailed steps for obtaining a blood sample from the fingertip for testing.

Recognizing High or Low Blood Glucose Symptoms

Lists common symptoms associated with hyperglycemia and hypoglycemia.

Preparing the Lancing Device

Lancing Device Setup and Usage

Instructions on how to prepare and adjust the lancing device for use.

Executing the Blood Glucose Test

Inserting the Test Strip into the Meter

Steps for correctly inserting the test strip into the meter's test strip port.

Applying Blood to the Test Strip

Guides on how to apply the blood sample to the test strip tip.

Managing Blood Samples and Results

Second-Chance Sampling Method

Explains how to apply more blood to the same test strip if the initial sample is insufficient.

Selecting Meal Markers for Results

Details how to select and assign meal markers to recorded test results.

Managing Meal Markers

Choosing and Confirming Meal Markers

Steps to select, change, and confirm meal markers on the meter.

Setting Reminders and Indicators

Setting Test Reminders

Instructions for setting up timed reminders for blood glucose testing.

Using the smartLIGHT Target Range Indicator

Explains the color-coded feedback system for target range results.

Interpreting Test Results

Viewing and Understanding Results

How to view test results and understand normal, high, or low readings.

Handling LO or HI Result Indicators

Guidance on interpreting and responding to 'LO' or 'HI' readings on the meter.

Lancet Disposal and Quality Control

Safe Ejection and Disposal of Lancets

Procedures for safely removing and disposing of used lancets.

Performing Control Solution Tests

Importance and when to perform control tests for meter accuracy.

Control Solution Testing Procedure

Steps for Control Solution Testing

Detailed steps for conducting a control solution test with the meter.

Using the Meter Logbook

Reviewing Past Test Results

How to access and navigate the meter's logbook to view historical data.

Meter Settings and Averages

Accessing and Navigating Meter Settings

Instructions on how to enter and browse through the meter's settings menu.

Viewing Blood Glucose Averages

How to view 7, 14, 30, and 90-day averages of blood glucose readings.

Configuring Meter Settings: Time

Adjusting Time and Time Format

Steps to change the meter's current time and time format (12/24 hour).

Configuring Meter Settings: Date and Sound

Adjusting Date and Date Format

Instructions for changing the meter's date and date format (m/d or d.m).

Configuring Sound Settings

How to turn the meter's sound notifications on or off.

Configuring Meter Settings: Markers

Setting Meal Markers

Enabling and disabling the meal marker feature on the meter.

Configuring Meter Settings: Target Ranges

Changing Overall Target Range

How to set or modify the meter's default overall target blood glucose range.

Configuring Meter Settings: Individual Ranges

Changing Individual Target Ranges

Instructions for setting specific target ranges for Before Meal and After Meal.

Configuring Meter Settings: Indicators

Setting smartLIGHT Indicator

How to enable or disable the smartLIGHT color-coded feedback feature.

Setting Bluetooth Wireless Functionality

Instructions for turning Bluetooth connectivity on or off for data transfer.

Using the CONTOUR DIABETES App

App Features and Benefits

Details the capabilities of the CONTOUR DIABETES app for managing glucose data.

Downloading and Pairing the App

Steps to download, install, and pair the CONTOUR DIABETES app with the meter.

Meter Care and Help Resources

Meter Care and Maintenance

Guidelines for proper storage, handling, and cleaning to maintain the meter.

Cleaning and Disinfection Procedures

Cleaning Your Meter

Step-by-step instructions for cleaning the blood glucose meter.

Information on Cleaning and Disinfection

Additional details and references regarding cleaning and disinfection processes.

Disinfecting Meter and Data Transfer

Disinfecting Your Meter

Procedure for disinfecting the meter using approved wipes.

Transferring Test Results

Methods for transferring blood glucose data to a computer or smartphone.

Battery Management and Replacement

Replacing Meter Batteries

Detailed instructions for safely replacing the meter's batteries.

Technical Information: Error Codes

Error Detection Displays and Solutions

Lists common error codes and provides steps to resolve them.

Technical Information: System Performance

User Accuracy Study Results

Presents data from a study on the meter's accuracy with typical users.

Measurement Repeatability and Precision

Details the results of studies on the meter's precision and repeatability.

Technical Information: Compliance and Standards

FCC Certified Device Information

Statement regarding the meter's compliance with Federal Communications Commission regulations.

Technical Information: Specifications and Symbols

Detailed System Specifications

Comprehensive list of the meter's technical specifications and operating parameters.

Product Labeling Symbols Explained

Defines the meaning of various symbols found on the product labeling.

Technical Information: Device Principles

ISO and IEC Standard Symbols

Explanation of symbols used according to ISO and IEC standards.

Principles of the Blood Glucose Test Procedure

Describes the scientific basis of how the meter measures blood glucose.

Technical Information: References

Cited References and Resources

Lists external documents and resources referenced within the manual.

Warranty Information and Limitations

Manufacturers Warranty Terms

Details the warranty period, coverage, and conditions for the meter.

Warranty Limitations and Exclusions

Outlines specific exceptions and limitations to the product warranty.

Summary

Contour Next GEN Blood Glucose Meter User Guide

System Overview and Key Features

Introduces the Contour Next GEN meter, highlighting features like NO CODING and Second-Chance sampling.

Getting Started with Your Contour Next GEN

Customer Service and Kit Contents

Provides contact info for customer service and lists items included in the meter kit.

Intended Use of the Monitoring System

Details the purpose and scope of the blood glucose monitoring system.

Important Safety Information

General Safety Warnings and Precautions

Covers critical warnings regarding testing, biohazards, and hygiene practices.

Consulting Your Healthcare Professional

Advises on when and why to consult a healthcare provider for test results.

System Specifications and Limitations

Device Limitations and Serious Illness

Outlines limitations for specific patient conditions and system usage constraints.

Operating and Storage Environment

Specifies temperature and humidity ranges for meter and strip operation and storage.

System Precautions and Meter Features

Handling, Battery, and Usage Precautions

Details precautions for battery safety, device handling, and environmental exposure.

Meter Features and Specifications Overview

Describes meter features like 'Easy' and 'Automatic' operation, measuring range, etc.

Getting Started: Meter Operation

Your CONTOUR NEXT GEN Meter

An overview of the physical meter, including buttons and ports.

Navigating the Meter Interface

Explains how to use the meter's buttons for navigation and selection.

Understanding the Meter Display

Meter Screen Symbols Explained

Defines the meaning of various symbols displayed on the meter screen.

Preparing for Blood Glucose Testing

Using the CONTOUR NEXT Test Strip

Instructions on how to insert and use the test strip correctly in the meter.

Understanding Target Ranges

Explains how the meter compares results to set target ranges.

Blood Glucose Testing Procedures

Using Meal Markers

Guides on how to apply meal markers to test results for tracking.

Getting Ready to Test

Steps and checks to perform before starting a blood glucose test.

Performing a Blood Glucose Test

Fingertip Blood Sample Collection

Detailed steps for obtaining a blood sample from the fingertip for testing.

Recognizing High or Low Blood Glucose Symptoms

Lists common symptoms associated with hyperglycemia and hypoglycemia.

Preparing the Lancing Device

Lancing Device Setup and Usage

Instructions on how to prepare and adjust the lancing device for use.

Executing the Blood Glucose Test

Inserting the Test Strip into the Meter

Steps for correctly inserting the test strip into the meter's test strip port.

Applying Blood to the Test Strip

Guides on how to apply the blood sample to the test strip tip.

Managing Blood Samples and Results

Second-Chance Sampling Method

Explains how to apply more blood to the same test strip if the initial sample is insufficient.

Selecting Meal Markers for Results

Details how to select and assign meal markers to recorded test results.

Managing Meal Markers

Choosing and Confirming Meal Markers

Steps to select, change, and confirm meal markers on the meter.

Setting Reminders and Indicators

Setting Test Reminders

Instructions for setting up timed reminders for blood glucose testing.

Using the smartLIGHT Target Range Indicator

Explains the color-coded feedback system for target range results.

Interpreting Test Results

Viewing and Understanding Results

How to view test results and understand normal, high, or low readings.

Handling LO or HI Result Indicators

Guidance on interpreting and responding to 'LO' or 'HI' readings on the meter.

Lancet Disposal and Quality Control

Safe Ejection and Disposal of Lancets

Procedures for safely removing and disposing of used lancets.

Performing Control Solution Tests

Importance and when to perform control tests for meter accuracy.

Control Solution Testing Procedure

Steps for Control Solution Testing

Detailed steps for conducting a control solution test with the meter.

Using the Meter Logbook

Reviewing Past Test Results

How to access and navigate the meter's logbook to view historical data.

Meter Settings and Averages

Accessing and Navigating Meter Settings

Instructions on how to enter and browse through the meter's settings menu.

Viewing Blood Glucose Averages

How to view 7, 14, 30, and 90-day averages of blood glucose readings.

Configuring Meter Settings: Time

Adjusting Time and Time Format

Steps to change the meter's current time and time format (12/24 hour).

Configuring Meter Settings: Date and Sound

Adjusting Date and Date Format

Instructions for changing the meter's date and date format (m/d or d.m).

Configuring Sound Settings

How to turn the meter's sound notifications on or off.

Configuring Meter Settings: Markers

Setting Meal Markers

Enabling and disabling the meal marker feature on the meter.

Configuring Meter Settings: Target Ranges

Changing Overall Target Range

How to set or modify the meter's default overall target blood glucose range.

Configuring Meter Settings: Individual Ranges

Changing Individual Target Ranges

Instructions for setting specific target ranges for Before Meal and After Meal.

Configuring Meter Settings: Indicators

Setting smartLIGHT Indicator

How to enable or disable the smartLIGHT color-coded feedback feature.

Setting Bluetooth Wireless Functionality

Instructions for turning Bluetooth connectivity on or off for data transfer.

Using the CONTOUR DIABETES App

App Features and Benefits

Details the capabilities of the CONTOUR DIABETES app for managing glucose data.

Downloading and Pairing the App

Steps to download, install, and pair the CONTOUR DIABETES app with the meter.

Meter Care and Help Resources

Meter Care and Maintenance

Guidelines for proper storage, handling, and cleaning to maintain the meter.

Cleaning and Disinfection Procedures

Cleaning Your Meter

Step-by-step instructions for cleaning the blood glucose meter.

Information on Cleaning and Disinfection

Additional details and references regarding cleaning and disinfection processes.

Disinfecting Meter and Data Transfer

Disinfecting Your Meter

Procedure for disinfecting the meter using approved wipes.

Transferring Test Results

Methods for transferring blood glucose data to a computer or smartphone.

Battery Management and Replacement

Replacing Meter Batteries

Detailed instructions for safely replacing the meter's batteries.

Technical Information: Error Codes

Error Detection Displays and Solutions

Lists common error codes and provides steps to resolve them.

Technical Information: System Performance

User Accuracy Study Results

Presents data from a study on the meter's accuracy with typical users.

Measurement Repeatability and Precision

Details the results of studies on the meter's precision and repeatability.

Technical Information: Compliance and Standards

FCC Certified Device Information

Statement regarding the meter's compliance with Federal Communications Commission regulations.

Technical Information: Specifications and Symbols

Detailed System Specifications

Comprehensive list of the meter's technical specifications and operating parameters.

Product Labeling Symbols Explained

Defines the meaning of various symbols found on the product labeling.

Technical Information: Device Principles

ISO and IEC Standard Symbols

Explanation of symbols used according to ISO and IEC standards.

Principles of the Blood Glucose Test Procedure

Describes the scientific basis of how the meter measures blood glucose.

Technical Information: References

Cited References and Resources

Lists external documents and resources referenced within the manual.

Warranty Information and Limitations

Manufacturers Warranty Terms

Details the warranty period, coverage, and conditions for the meter.

Warranty Limitations and Exclusions

Outlines specific exceptions and limitations to the product warranty.

Contour Next GEN 9658 Specifications

General IconGeneral
BrandContour
ModelNext GEN 9658
CategoryBlood Glucose Meter
LanguageEnglish