Maximum Electrical Specifications
ITEM DESCRIPTION LIMIT
Input Voltage Maximum input AC voltage 120/240 VAC
Input Current Maximum input current 5.0 A
Relay Voltage Maximum relay voltage 240 VAC
Relay Current Maximum Relay Current 2.5 A
Standby Current Maximum operating current 0.1 A Max
Fuse Rating F1 5A, 250V, 05x20
Fuse Rating F2 5A, 250V, 05x20
Fuse Rating F3 1A, 250V, 05x20
pH Measurement of pH 4.22 to 9.98
ORP Oxidation Reduction Potential 0 to 999 mV
Free Chlorine - PPM
With optional TrueDPD sensor NSF Certified Range
0 to 6.0 PPM 10%
Free Chlorine - PPM Extended non-NSF Certified Range 6.0 to 9.5 PPM 20%
Certifications
NSF/ANSI 50 - Equipment
for Swimming Pools, Spas,
Hot Tubs and Other
Recreational Water Facilities
http://info.nsf.org/Certified/Pools/Listi
ngs.asp?Company=C0214550&Stan
dard=050&
4010758
Conforms to
UL STD 1563
Certified to CSA STD
C22.2 No. 218.1
Environmental Specifications
ITEM DESCRIPTION LIMIT
Elevation Not to be used above 2000 m
Temperature Minimum/Maximum Operating Temperature 30/110 °F
Temperature Water temperature measurement. 32 to 122 °F
IP Rating Suitable for Outdoor Use IPX3
Pollution Pollution Degree 2