CONTROLS, INCORPORATED
C O N T R O L S Y S T E M S & S O L U T I O N S
- 9 -
CONTROL PANEL ANALOG AND DIGITAL INPUTS
The panel has one analog input and up to three digital inputs available to monitor other
components, senders or signals. These inputs can be used for a number of purposes including
alarms and shut downs.
Input
Heading
Default
Options
Connector
Pin
Analog 1
Function
Fuel Level S-W
A
5
Digital 1
Normally
Open
Open / Closed
A
4
Function
Discrete Speed
Message
None
Check
Always
Off / Always / Run
Digital B1
Action
Throttle Up
B
2
Digital B2
Action
Throttle Down
B
5
Digital Inputs should be configured as open circuits, which close to ground.
Closing to battery positive will damage the electronics.