Service Handbook OEB/OES/OGB/OGS
6.17.3 Replacing outer door on table and standing units
Check:
Scratches on the glass panel of the outer door
Panel is broken
Safety:
Maintenance and repair work should only be performed on a cold unit.
Do not open inner door at temperatures > 80°C.
Secure the screws with screw locking lacquer ( i.e. Loctite).
Instructions – Removing the outer door:
Remove the inner door 2 (see 6.17.1 and 6.17.2 Instructions for table and
standing units).
Mark the setting of the upper hinge plate with a marker before removing.
Holding the door, unscrew the screws and remove hinge plate.
Lift the door up and out of the hinge.
Instructions – Replacing the outer door:
Lower the door onto the setting.
Place the upper hinge plate in the door and fasten it with washer, spring
washer and screw onto the slot panel - don’t tighten yet!
Place the hinge plate on the marked setting and tighten screw.
distance of closed door to front piece = 10 mm
door upper edge must be horizontal.
Secure the screw with screw locking lacquer i.e. Loctite.
Assemble the inner door 2 again (see 6.17.1 and 6.17.2 Instructions for table
and standing units).
AS/11-2011 6_17e_Inner and outer door replacement_b