Service manual OEB/OES/OGB/OGS
5_00e Troubleshooting list_L 6/27 2013-01-30
E
T
O
E
B
O
E
S
O
G
B
O
G
S
Error-
message
Error description possible cause or remedy
Start speed at the burner HA2 not reached
possibly voltage supply disturbed
E05.6-1
ID53
No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
PWM signal interrupted
E05.6-2
ID53
No gas
(only 20.10 / 20.20)
Start speed at the burner HA2 not reached
possibly voltage supply disturbed
E05.7.xxx
No gas
Full load speed at the burner HA1 not reached
PWM signal interrupted
Full load speed at the burner HA1 not reached
possibly voltage supply disturbed
E05.8.xxx
No gas
Full load speed at the burner steam generator not
reached
PWM signal interrupted
Full load speed at the burner steam generator not
reached
possibly voltage supply disturbed
E05.9.xxx
No gas
(only 20.10 / 20.20)
Full load speed at the burner HA2 not reached
PWM signal interrupted
Full load speed at the burner HA2 not reached
possibly voltage supply disturbed
E05.10.x
xx
ID52
No gas
(from Software 4.15)
Wait 40 seconds, if
there is no ‘Flame OK’
or ‘Alarm Signal’
Interruption of flame OK or Alarm Signal between flame
controller - control module HL1.
Check connection between FA and CM / GM:
CM: for OGS 6.10 to OGS 12.20: X14:1/2 and X15:12
(for units without GM)
GM: Plug X20:5/6 and X25:10
FA: Clamps 1, 2, 5
E05.11.x
xx
ID54
No gas
(from Software 4.15)
Wait 40 seconds, if
there is no ‘Flame OK’
or ‘Alarm Signal’
Interruption of Flame OK or Alarm signal between flame
controller - SG control.
Check connection between FA and GM:
GM: Plug X21:4/5 and X25:11
FA: Clamps 1, 2, 5
E05.12.x
xx
ID53
No gas
(from Software 4.15)
Wait 40 seconds, if
there is no ‘Flame OK’
or ‘Alarm Signal’
Interruption of Flame OK or Alarm signal between flame
controller - control module HL2.
Check connection between FA and GM:
GM: Plug X22:4/5 and X25:12
FA:Clamps 1, 2, 5
E11.xxx
ID23
Oven sensor (B6
thermoelement)
excessive temperature
(Temperature on the
sensor >300°C)
Hot air contactors do not switch off (burnt together)
Motor not operating (e.g. because of 2 defective
miniature fuses F10, not with the 6.06 as F10 protects
the CM).
ID25
Core Temperature
Probe 1 – Over
CTC probe has temperature higher than the maximum
acceptable value (sensor not correctly inserted into the food