2.0 Putting Into Operation
Position the device where it is protected from sunlight and other
heat sources, since operation may be disturbed if the ambient
temperature exceeds +25°C/77°F.
The appliance should not be operated in rooms where the
temperature drops below +10°C/50°F since this disrupts the
lubrication of the compress
Leave at least 10 cm/3.9 inches space between the appliance’s
side walls/roof/back and neighbouring surfaces such as other
devices, walls, furniture and ceiling to provide free air ow be-
hind the device to enable proper operation.
If the furnishing of the room allows positioning only close to the
heat source the following minimum clearances must be kept: or.
• Put a 0.5-1cm/0.393 inches thick insulation board between
two devices if they are 3 cm/1.18 inches or less apart.
• Min. 30 cm/11.8 inches from oil or coal-red ovens.
The appliance may be connected to 110 V mains via proper-
ly mounted grounded socket. Check if the voltage meets the
local voltage and make sure that the connecting cable isn’t stuck
anywhere.
A fuse/circuit breaker of 10 A is required for the operation
of the appliance.
If the connection cable is damaged or it has to be extended,
the job must be done by a qualied electrician to avoid the
dangerous situations.
Do not use an extension cord! The appliance must be positioned
in a way that the main plug is easily accessible.
2.2. Electrical Connection
IMPORTANT!
Never move the appliance by grasping the sides.
2.1. Installation
7
WARNING!
Keep all ventilation openings in the appliance clear of obstructions.