LOW BATT RESTORE (see note 6) YR 311‡
PARTITION RESET OR 305
RESET OR 305
INTERMEDIATE
Event SIA Code CID Code
ARM CL 401
DISARM OP 401
KEYSWITCH DISARM OS 409
KEYSWITCH ARM CS 409
ZONE FAULT IA 389
ZONE FAULT RESTORE IR 389
FULL
Event SIA Code CID Code
COMMS FAIL - 350
DOWNLOAD SUCCESS RS 412
EXCESS KEYS JA 461
EXPANDER MISSING TA 137
EXPANDER MISSING RESTORE TR 137‡
FORBI MISSING TA 137
FORBI MISSING RESTORE TR 137‡
JAMMING XQ 380
PASSWORD DEFAULTS LOADED RH -
PROG MODE START LB 627
PROG MODE END LS 628
TD (Time and day) RESET JT 625
TX BATTERY TROUBLE XT 384
USER CODE CHANGED JV -
USER CODE DELETED JX -
Notes:
1. If Command 143, option 1 is selected, all messages with a CID Code are sent. If
option 0 is selected, the restores marked with ‡ are not sent.
2. This message also sent for PAs started from a telecommand.
3. The control unit logs an Anti-Mask event to the zone number one below that assigned
the Anti-Mask type.
4. This message also sent for Power zones.
5. This message also sent for Battery Fault zones.
6. This message also sent for Low Battery zones.
Command 141: Alert Tone On/Off
This is a new command in version 5.0x. Use this command to disable the
Alert fault tones. When enabled (default) the system gives an alert tone and
displays alerts on the keypad.

Other manuals for Cooper Security Scantronic 9752

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cooper Security Scantronic 9752 and is the answer not in the manual?

Cooper Security Scantronic 9752 Specifications

General IconGeneral
BrandCooper Security
ModelScantronic 9752
CategoryControl Unit
LanguageEnglish

Related product manuals