EasyManua.ls Logo

Cooper Surgical frigitronics CE-2000 User Manual

Cooper Surgical frigitronics CE-2000
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CE-2000
A Low-Pressure, Non-Electric Fully Exhausted Cryosurgical System
with Backlight Digital Temperature Display
Instructions for Use (English)
Gebruiksaanwijzingen (Deutsch / German)
Modo de empleo (Español / Spanish)
Mode d’emploi (Français / French)
Istruzioni per l’uso (Italiano / Italian)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Cooper Surgical frigitronics CE-2000 and is the answer not in the manual?

Cooper Surgical frigitronics CE-2000 Specifications

General IconGeneral
BrandCooper Surgical
Modelfrigitronics CE-2000
CategoryMedical Equipment
LanguageEnglish

Summary

Identification

Front View

Labeled diagram of the console's front panel, showing key components.

Rear View

Labeled diagram of the console's rear panel and attached gas cylinders.

Specifications

Technical details including dimensions, weight, and pressure ranges.

Introduction

Indications for Use

Specifies the intended medical applications for the cryosurgical system.

Caution Statements

Important warnings and precautions for safe and proper use of the device.

Information Statements

Provides general information about the device's operation and materials.

Unpacking and Set-up

Instructions for unboxing and initial assembly of the cryosurgical system.

Checking the System

Gas Exhaust

Procedures for safely venting nitrous oxide gas exhaust from the system.

Installation of Probes

Guidelines for correctly connecting cryosurgical probes to the console.

Installation of Thermocouple Probes

Specific instructions for installing probes with temperature sensing capabilities.

Digital Temperature Display with Backlight

Information on the function and battery requirements of the temperature display.

Operation of System

To Exchange Probes

Step-by-step guide for safely replacing cryosurgical probes.

To Exchange Cylinders

Procedure for safely swapping nitrous oxide gas cylinders.

Shut Down

Instructions for properly turning off and securing the cryosurgical system.

Care and Maintenance

Guidelines for cleaning and general upkeep of the cryosurgical system.

Troubleshooting

Probe does not freeze properly

Addresses issues where the probe tip fails to achieve freezing temperatures.

Probe does not defrost properly

Solutions for when the probe tip does not warm up or thaw as expected.

Premature defrost

Troubleshooting steps for unexpected thawing of the probe tip during operation.

Digital Temperature Display - no temperature or backlight

Diagnosing issues with the temperature display or its backlight functionality.

On/Off valve or pressure regulator knob does not operate properly

Rectifying problems with control knob functionality on the console.

Difficult to insert probe into probe socket/or leaks

Resolving problems with probe insertion and potential leaks at the connection point.

Exhaust hose slips off console or probe

Fixing issues where exhaust hoses detach from the console or probe.

User Information

Replacement Parts for Console

Lists part numbers and descriptions for console components.

Replacement Parts for Mobile Carriers

Lists part numbers and descriptions for mobile carrier components.

Cryosurgical Probes

Ophthalmology Probes

Details on various probes for ophthalmic procedures, including specs.

Pediatric Retinal

Specific probes designed for pediatric retinal cryosurgery.

Trichiasis

Probes indicated for the treatment of trichiasis.

Probe Sterilization

Recommended Sterilization Procedures

Guidance on steam and ethylene oxide sterilization methods for probes.

Sleeve Sterilization

Instructions for sterilizing probe sleeves separately or attached.

Cartridge Replacement

Procedure for replacing the filter assembly cartridges.

Warranty

Explanation of Symbols