Functions
3
ErrorMessages
●Youcanselectswitchworkingmodefromtheoptionsshowninthetablebelow.
(Note1)IntheSeparateMode,SW1andSW2workseparately.
(Note2)IntheWindowComparatorMode,theminimumvalueforSW1andSW2correspondstoSetting1andthemaximumvaluetoSetting2.
※Forhowtosettheswitchoutput,seethedescriptionoftheinitialsettingmode.
●Whenyoudonotoperateanybuttonsforabout10seconds,thesystemwillautomaticallyselectnon-displaymode
andtheLEDindicatorsectionwillgooff.PressinganykeywillcausetheLEDindicatorsectiontocomeonbackagain.
(Note1)Thedecimalpointshowninthefigureontherightblinksduringnon-displaymode.
(Note2)SwitchoutputsandswitchLEDsareoperableevenduringnon-displaymode.
(Note3)Noerrormessageswillappearduringnon-displaymode.
※Forhowtoselectnon-displaymode,seethedescriptionoftheinitialsettingmode.
●Twodifferentdigitalfilters(25msand250ms)areavailable.
Thedigitalfiltersareusefulwhenitishardtotakereadingsduetotoogreatfluctuationsinpressure.
(Note1)Anyselecteddigitalfilterwillbereflectedonthepressuredisplayandswitchaction.
※Forhowtosetthedigitalfilter,seethedescriptionofthepressuresettingmode.
■Ifthefollowingerrormessagesaredisplayed,followtheproceduresinthetable:
Switchworkingmode
Digitalfilter
Conversionfactor
Non-displaymode
(Note1)Noerrormessageswillbeshownwhennon-displaymodeisselected.
(Note2)Whentheappliedpressureexceeds110%ofratedpressure,thedisplayindicate“flashing”or“−L−”or“−H−”.
Thisdisplayedvalueisnotaccuratevalue,pleaseusewithintheratedpressurerange.
●Youcanselectaconversionfactorfromtheoptionsshowninthetableontheright.
(Note1)Slashedbox:Nofactorsoptionsareavailableduetoinappropriateresolution
andthenumberofdigitsfordisplay.
※Forhowtosettheconversionfactor,seethedescriptionoftheinitialsettingmode.
Errormessage
Problem Solution
Overloadcurrent.(BrinkingofSW1orSW2indicates
excessivecurrentonSW1orSW2.)
Appliedpressureishigherthanthemaximumvalue
ofthepressuredisplayrange.
Pressuredetectedwhenadjustingthezeropoint.
ExaminationbyNidecCopalElectronicsisrequired.
Pressurevalueexceeds110%oftherating.(Thiserrorexamples
whenthepressuremorethan111kpaisappliedtothe102Rmodele.)
Appliedpressureishigherthanthemaximumvalue
ofthepressuredisplayrange.
Checktheappliedpressure.
Checktheappliedpressure.
Checktheappliedpressure.
Pressthe buttonandresetthe display.Releasetheappliedpressure
inthepressureport(openedtotheatmosphere)andadjustthezeropointagain.
TelephonethenearestofficeorSensorDepartmentofNidec
CopalElectronicsCorp.
Disconnectthepower,thenchecktheloadcondition.
M
PS30SW1
kPaSW2
Number
selected
Pressurerange
102R
Factor
×1
×0.75
×0.01
×0.145
Displayrange
-100〜100
-
75〜75
-
1.00〜1.00
-
14.5〜14.5
Factor
×1
×10
×145
Displayrange
-0.10〜1.00
-1.0〜10.0
-14〜145
103R
Output
Mode
Operation
Numberselected
SW1
Separate
H
○
○
L
○
○
A
○
○
B
○
○
H
○
○
L
○
○
A
○
○
B
○
○
WindowComparator
Note1
Setting1
Note2
Minimum:Setting1
Maximum:Setting2
Minimum:Setting1
Maximum:Setting2
Note1
Setting2
Note2
Separate
WindowComparator
SW2
Therearefouroperationmodes.Thereareshowninthediagramsbelow.
SeparateMode
P1:Setting1,P2:Setting2,H:Hysteresis
WindowComparatorMode
(HIoperation)
OFF
ON
-Pr Pr
H
H
P1:SW1 P2:SW2
ON
OFF
-Pr Pr
H
H
P1:SW1 P2:SW2
(LOoperation)
(Aoperation)
OFF
ON
ON
-Pr
Pr
H H
P1 P2
P1 P2
(Boperation)
OFF
OFF
ON
-Pr
Pr
H H
P1≦P2 or P1≧P2 P1≦P2−2H