EasyManua.ls Logo

Copley Controls Xenus XTL Series - Page 3

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus XTL
Copley Controls, 20 Dan Road, Canton, MA 02021, USA Tel: 781-828-8090 Fax: 781-828-6547
Tech Support: E-mail: sales@copleycontrols.com, Internet: http://www.copleycontrols.com Page 3 of 30
RoHS
DIGITAL SERVO DRIVE
for BRUSHLESS/BRUSH MOTORS
ENCODER
DIGITAL QUAD A/B ENCODER
Type Quadrature, differential line driver outputs
Signals A, /A, B, /B, (X, /X, index signals optional)
Frequency 5 MHz line frequency, 20 MHz quadrature count frequency
ANALOG ENCODER
Type Sin/cos, differential line driver outputs, 0.5 Vpeak-peak (1.0 Vpeak-peak differential)
centered about 2.5 Vdc typical. Common-mode voltage 0.25 to 3.75 Vdc
Signals Sin(+), sin(-), cos(+), cos(-)
Frequency 230 kHz maximum line (cycle) frequency
Interpolation 10 bits/cycle (1024 counts/cycle)
DIGITAL HALLS
Type Digital, single-ended, 120° electrical phase difference
Signals U, V, W
Frequency Consult factory for speeds >10,000 RPM
ENCODER POWER SUPPLY
Power Supply +5 Vdc @ 400 mA to power encoders & Halls
Protection Current-limited to 750 mA @ 1 Vdc if overloaded
Encoder power developed from +24 Vdc so position information is not lost when AC mains power is removed
MOTOR CONNECTIONS
Phase U, V, W PWM outputs to 3-phase ungrounded Wye or delta connected brushless motors
Hall U, V, W Hall signals
Digital Encoder A, /A, B, /B, X, /X, on standard models
Analog Encoder Sin(+), sin(-), cos(+), cos(-), X, /X, on -S versions (X & /X index signals are digital)
Hall & encoder power +5 Vdc @ 400 mA maximum
Motemp [IN5] Motor overtemperature sensor input, 4.99 k to +5 Vdc or ground
Signal ground Return for encoder, Halls, and temperature sensor
Brake [OUT4] Current-sinking motor brake driver
+24 Vdc From drive +24 Vdc power supply to power motor brake
Frame ground For motor cable shield
FEEDBACK SPECIFICATIONS
GENERAL SPECIFICATIONS (CONTINUED)
PROTECTIONS
HV Overvoltage +HV > 400 Vdc Drive PWM outputs turn off until +HV is less than overvoltage
HV Undervoltage +HV < 60 Vdc Drive PWM outputs turn off until +HV is greater than undervoltage
Drive over temperature IGBT > 80 °C ±3 °C Drive PWM outputs turn off until IGBT temperature is below threshold
Short circuits Output to output, output to ground, internal PWM bridge faults
I
2
T Current limiting Programmable: continuous current, peak current, peak time
Motor over temperature Drive shuts down when motor over-temperature switch changes to high-resistance state, or opens
Feedback power loss Fault occurs if feedback is removed or +5 V is <85% of normal
MECHANICAL & ENVIRONMENTAL
Size 7.55 in (191,8 mm) X 5.57 in (141,5 mm) X 2.57 in (65,3 mm)
Weight 3.0 lb (1.36 kg) for drive without heatsink
1.9 lb (0.86 kg) for XTL-HS heatsink, 1.26 lb (0.57 kg) for XTL-HL heatsink
Ambient temperature 0 to +45 °C operating, -40 to +85 °C storage
Humidity 0% to 95%, non-condensing
Vibration 2 g peak, 10~500 Hz (sine), IEC60068-2-6
Shock 10 g, 10 ms, half-sine pulse, IEC60068-2-27
Contaminants Pollution degree 2
Environment IEC68-2: 1990
Cooling Heat sink and/or forced air cooling required for continuous power output
AGENCY STANDARDS CONFORMANCE
EN 55011 : 1998 CISPR 11 (1997) Edition 2/Amendment 2:
Limits and Methods of Measurement of Radio Disturbance Characteristics of Industrial, Scientic, and
Medical (ISM) Radio Frequency Equipment
EN 61000-6-1 : 2001 Electromagnetic Compatibility Generic Immunity Requirements
Following the provisions of EC Directive 89/336/EEC:
EN 61010-1 2nd Ed.: 2004 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory use
Following the provisions of EC Directive 2006/95/EC:
UL 508C 3rd Ed.: 2002 UL Standard for Safety for Power Conversion Equipment

Related product manuals