DIGITAL SERVO DRIVE
for BRUSHLESS/BRUSH MOTORS
ENCODER
DIGITAL QUAD A/B ENCODER
Type Quadrature, differential line driver outputs
Signals A, /A, B, /B, (X, /X, index signals optional)
Frequency 5 MHz line frequency, 20 MHz quadrature count frequency
ANALOG ENCODER
Type Sin/cos, differential line driver outputs, 0.5 Vpeak-peak (1.0 Vpeak-peak differential)
centered about 2.5 Vdc typical. Common-mode voltage 0.25 to 3.75 Vdc
Signals Sin(+), sin(-), cos(+), cos(-)
Frequency 230 kHz maximum line (cycle) frequency
Interpolation 10 bits/cycle (1024 counts/cycle)
DIGITAL HALLS
Type Digital, single-ended, 120° electrical phase difference
Signals U, V, W
Frequency Consult factory for speeds >10,000 RPM
ENCODER POWER SUPPLY
Power Supply +5 Vdc @ 400 mA to power encoders & Halls
Protection Current-limited to 750 mA @ 1 Vdc if overloaded
Encoder power developed from +24 Vdc so position information is not lost when AC mains power is removed
MOTOR CONNECTIONS
Phase U, V, W PWM outputs to 3-phase ungrounded Wye or delta connected brushless motors
Hall U, V, W Hall signals
Digital Encoder A, /A, B, /B, X, /X, on standard models
Analog Encoder Sin(+), sin(-), cos(+), cos(-), X, /X, on -S versions (X & /X index signals are digital)
Hall & encoder power +5 Vdc @ 400 mA maximum
Motemp [IN5] Motor overtemperature sensor input, 4.99 kΩ to +5 Vdc or ground
Signal ground Return for encoder, Halls, and temperature sensor
Brake [OUT4] Current-sinking motor brake driver
+24 Vdc From drive +24 Vdc power supply to power motor brake
Frame ground For motor cable shield
FEEDBACK SPECIFICATIONS
GENERAL SPECIFICATIONS (CONTINUED)
PROTECTIONS
HV Overvoltage +HV > 400 Vdc Drive PWM outputs turn off until +HV is less than overvoltage
HV Undervoltage +HV < 60 Vdc Drive PWM outputs turn off until +HV is greater than undervoltage
Drive over temperature IGBT > 80 °C ±3 °C Drive PWM outputs turn off until IGBT temperature is below threshold
Short circuits Output to output, output to ground, internal PWM bridge faults
I
2
T Current limiting Programmable: continuous current, peak current, peak time
Motor over temperature Drive shuts down when motor over-temperature switch changes to high-resistance state, or opens
Feedback power loss Fault occurs if feedback is removed or +5 V is <85% of normal
MECHANICAL & ENVIRONMENTAL
Size 7.55 in (191,8 mm) X 5.57 in (141,5 mm) X 2.57 in (65,3 mm)
Weight 3.0 lb (1.36 kg) for drive without heatsink
1.9 lb (0.86 kg) for XTL-HS heatsink, 1.26 lb (0.57 kg) for XTL-HL heatsink
Ambient temperature 0 to +45 °C operating, -40 to +85 °C storage
Humidity 0% to 95%, non-condensing
Vibration 2 g peak, 10~500 Hz (sine), IEC60068-2-6
Shock 10 g, 10 ms, half-sine pulse, IEC60068-2-27
Contaminants Pollution degree 2
Environment IEC68-2: 1990
Cooling Heat sink and/or forced air cooling required for continuous power output
AGENCY STANDARDS CONFORMANCE
EN 55011 : 1998 CISPR 11 (1997) Edition 2/Amendment 2:
Limits and Methods of Measurement of Radio Disturbance Characteristics of Industrial, Scientic, and
Medical (ISM) Radio Frequency Equipment
EN 61000-6-1 : 2001 Electromagnetic Compatibility Generic Immunity Requirements
Following the provisions of EC Directive 89/336/EEC:
EN 61010-1 2nd Ed.: 2004 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory use
Following the provisions of EC Directive 2006/95/EC:
UL 508C 3rd Ed.: 2002 UL Standard for Safety for Power Conversion Equipment