Isolate the range from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 psi (3.5 kPa or 14" water column).
ASSEMBLY OF THE
BURNERS
The electrode of the electronic ignition system is positioned above the surface of the burner base. Do
not remove a burner cap or touch the electrode of a burner while another is turned on. Damage or
electrical shock may occur.
1. Place burner heads ov
er the burner base.
Make sure the hole in the burner head is
properly aligned with the electrode in the
burner base. (See Figure 13)
2. Place the burner
caps on the burner heads.
Make sure that the burner caps are
properly seated on the burner head. (See
Figure 14)
3. Operation of
the electric igniters should be
tested after the range and supply line have
been carefully checked for leaks and the
range has been connected to the electrical
power. To check igniters, push and turn a
sounds), but only the burner turned to LITE
will light.
Figure 13
Figure 14
25

Other manuals for Cosmo 965 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cosmo 965 Series and is the answer not in the manual?

Cosmo 965 Series Specifications

General IconGeneral
BrandCosmo
Model965 Series
CategoryRanges
LanguageEnglish

Related product manuals