OWNER’S MANUAL
4” Submersible Pumps
Two Wire
1/2 thru 1 HP, 60 Hz
MANUAL DEL USUARIO
Bombas sumergibles de 4”
bifilares
1/2 a 1 CV, 60 Hz
CLA200
CLA201
CLA202
CLA203
©2017 CL874 (Rev. 01/06/17)
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 800-535-4950
English................Pages 2-12
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 800-535-4950
Español ............ Páginas 13-23
293 Wright Street, Delavan, WI 53115
Phone: 800-535-4950
Fax: 800-526-3757
www.tractorsupply.com

Questions and Answers

  • C
    Charlotte MurrayAug 19, 2025
    What to do if my CountyLine CLA202 Water Pump has low voltage?
    • L
      Luis HarrisonAug 19, 2025
      Consider installing a larger wire from the meter to the pressure switch and from the pressure switch to the pump. If necessary, have the power company raise the supply voltage.
  • K
    Kevin SmithAug 21, 2025
    What to do if my CountyLine CLA202 Water Pump has low or high voltage?
    • H
      hardinlauraAug 21, 2025
      If the voltage variation is more than ±10%, contact your power company to adjust the voltage.
  • C
    Calvin WeeksAug 23, 2025
    What to do if my CountyLine Water Pump is stuck or binding?
    • A
      Anthony MendozaAug 25, 2025
      If necessary, pull the pump and perform all possible above-ground checks first. If the pump is locked, replace it. Prior to reinstalling the pump, make sure to clean the well of all sand or lime.
  • M
    Michael SimpsonAug 26, 2025
    What to do if my CountyLine CLA202 Water Pump has a tank waterlogged?
    • S
      stevenluceroAug 26, 2025
      If you have air-over-water tanks, repair or replace the tanks. If necessary, replace the air pressure valve.
  • A
    Anna DillonAug 27, 2025
    What to do if my CountyLine CLA202 pressure switch is defective?
    • A
      Amanda GreenAug 27, 2025
      Readjust or replace the pressure switch.
  • M
    Maria BaxterAug 29, 2025
    What to do if my CountyLine CLA202 has a plugged intake screen?
    • D
      davissaraAug 29, 2025
      Clean or replace the intake screen as necessary.
  • J
    Jennifer PrinceAug 31, 2025
    What to do if my CountyLine CLA202 Water Pump has wrong size fuse?
    • J
      James PhillipsAug 31, 2025
      Install the correct fuse or time delay fuse.
  • G
    gjohnsonSep 2, 2025
    What to do if my CountyLine CLA202 Water Pump has a wire size too small?
    • H
      heathermosesSep 3, 2025
      Install the correct size wire.
  • D
    david51Sep 4, 2025
    What to do if my CountyLine Water Pump has a leak in drop pipe?
    • A
      amanda82Sep 5, 2025
      Replace the pipe above the point where the leak occurs.
  • J
    johnstonjoanneSep 6, 2025
    What to do if my CountyLine CLA202 has low water level?
    • R
      Ryan FrenchSep 7, 2025
      Lower the pump further into the well, ensuring it remains at least 5’ (1.6m) above the bottom of the well. Adjust the pump discharge until it matches the recovery rate of the well. Note: Running the pump while airlocked can cause loss of prime and seriously damage the pump.

Summary

Safety

Important Safety Instructions

Contains essential safety instructions for installation, operation, and maintenance. Alerts user to potential hazards.

Installation

Before Installation

Guidance on inspecting the pump for damage and understanding warranty void conditions.

Electrical Grounding Information

Instructions for safely grounding the pump and motor to reduce electric shock hazards.

Wiring Connections

Details on meeting electrical codes and using appropriate copper wire for connections.

Installation Wiring Diagrams

Provides diagrams for correct hook-up information for 2-wire motors, adhering to electrical codes.

Cable Splicing

Outlines methods for splicing electrical cable to motor leads using taped or heat-shrink splices.

Power Supply Cable Installation

Guidelines for connecting the power supply cable, ensuring correct voltage and frequency.

Pump Installation

Instructions for installing the pump, including pressure tank hookup and safety rope.

Initial Start-Up

Procedure for starting the pump for the first time, especially for developing a well.

Connecting to Tank; Water System

Guidance on connecting the pump to the water system, including pressure relief valves and freezing prevention.

Troubleshooting

Motor Issues

Addresses problems like the motor not starting, fuse blows, or overload protector trips.

Pump Performance Problems

Covers issues such as the pump starting too frequently, leaks, or tank waterlogging.

Water Delivery Issues

Details problems like little or no water delivered and air or milky water discharge.

Warranty

Limited Warranty Terms

Outlines the 12-month warranty period, repair/replacement options, and required documentation.

Warranty Exceptions and Limitations

Details conditions not covered by warranty and limitations of remedies.

CountyLine CLA202 Specifications

General IconGeneral
BrandCountyLine
ModelCLA202
CategoryWater Pump
LanguageEnglish

Related product manuals