XII-1- L1 and h1 settings
1- Pressing M once brings us to L1 setting mode.
2-
L-1
appears for 2s.
3- Display then specifies existing setting (
65
, for example).
4- By pressing on + or , select the desired value:
- 0 to 99% if
uni
=
Pct
- 0 to -29.9 inHg if
uni
=
-iH
- 0 to -990 mbar if
uni
=
-bA
The selected value is automatically memorized. After 5 sec, automatic
return to vacuum level display
00
.
OR, if you wish to set h1, L1 hysteresis:
5- Press M once (during this 5 s delay) to bring us to h1 setting.
6-
h-1
appears for 2s.
7- Display then specifies existing setting (
10
, for example).
8- By pressing on + or , select the desired value:
- 0 to 99% if
uni
=
Pct
- 0 to -29.9 inHg if
uni
=
-iH
- 0 to -990 mbar if
uni
=
-bA
The selected value is automatically memorized. Then, return to vacuum
level display
00
.
XII-1- Einstellung von L1 und h1
1- Einmal auf M drücken, um auf den Betrieb zum Einstellen des
Grenzwerts des Signals „Werkstückaufnahme“ L1 zu schalten.
2-
L-1
erscheint für 2 Sek.
3- Auf dem Display wird dann der vorliegende Einstellwert angezeigt
(zum Beispiel
65
).
4- Durch Drücken von + oder den gewünschten Wert auswählen:
- 0 bis 99%, wenn
uni
=
Pct
- 0 bis -29.9 inHg, wenn
uni
=
-iH
- 0 bis -990 mbar, wenn
uni
=
-bA
Der ausgewählte Wert wird automatisch gespeichert. Die Rückkehr zur
Anzeige des Vakuumlevel
00
erfolgt automatisch nach 5 Sekunden.
ODER wenn Sie die Hysterese h1 von L1 einstellen wollen:
5- 1 Mal auf M (innerhalb dieser 5 Sekunden), um auf den Betrieb
zum Einstellen von h1 umzuschalten.
6-
h-1
erscheint für 2 Sek.
7- Auf dem Display wird dann der bestehende Einstellwert angezeigt
(zum Beispiel
10
).
8- Durch Drücken von + oder den gewünschten Wert auswählen:
- 0 bis 99%, wenn
uni
=
Pct
- 0 bis -29.9 inHg, wenn
uni
=
-iH
- 0 bis -990 mbar, wenn
uni
=
-bA
Der ausgewählte Wert wird automatisch gespeichert, dann folgt die
Rückkehr zur Anzeige des Vakummlevel
00
.
2s
2s
1
5
4
2 3
6 7
2s
8
5s
XII-2- L2 and h2 settings
1- Pressing M twice bring us to L2 setting mode.
2-
L-2
appears for 2s.
3- Display then specifies existing setting (
75
, for example).
4- By pressing on + or , select the desired value:
- 0 to 99% if
uni
=
Pct
- 0 to -29.9 inHg if
uni
=
-iH
- 0 to -990 mbar if
uni
=
-bA
The selected value is automatically memorized. After 5 sec, automatic
return to vacuum level display
00
.
OR, if you wish to set h2, L2 hysteresis:
5- Press on M (during this 5 s delay) to bring us to h2 setting.
6-
h-2
appears for 2s.
7- Display then specifies existing setting (
10
, for example).
8- By pressing on + or , select the desired value:
- 0 to 99% if
uni
=
Pct
- 0 to -29.9 inHg if
uni
=
-iH
- 0 to -990 mbar if
uni
=
-bA
The selected value is automatically memorized. Then, return to vacuum
level display
00
.
XII-2- Einstellung von L2 und h2
1- Zweimal auf M drücken, um auf den Betrieb zum Einstellen des
Grenzwerts „ASC“ L2 zu schalten.
2-
L-2
erscheint für 2 s.
3- Auf dem Display wird dann der bestehende Einstellwert angezeigt
(zum Beispiel
75
).
4- Durch Drücken von + oder den gewünschten Wert auswählen:
- 0 bis 99%, wenn
uni
=
Pct
- 0 bis -29.9 inHg, wenn
uni
=
-iH
- 0 bis -990 mbar, wenn
uni
=
-bA
Der ausgewählte Wert wird automatisch gespeichert. Die Rückkehr zur
Anzeige des Vakuumlevel
00
erfolgt automatisch nach 5 Sekunden.
ODER wenn Sie die Hysterese h2 von L2 einstellen wollen:
5- 1 Mal auf M drücken (innerhalb dieser 5 Sekunden), um auf den
Betrieb zum Einstellen von h2 umzuschalten.
6-
h-2
erscheint für 2 s.
7- Auf dem Display wird dann der bestehende Einstellwert angezeigt
(zum Beispiel
10
).
8- Durch Drücken von + oder den gewünschten Wert auswählen:
- 0 bis 99%, wenn
uni
=
Pct
- 0 bis -29.9 inHg, wenn
uni
=
-iH
- 0 bis -990 mbar, wenn
uni
=
-bA
Der ausgewählte Wert wird automatisch gespeichert, dann folgt die
Rückkehr zur Anzeige des Vakuumlevel
00
.
XII-1
XII-2
- 10 -