6. Place the shower head on the oor, set the faucet to the center
position and open the faucet.
7. While the regeneration is performed, the timer sound is heard and
the regeneration water is extracted through the shower hose.
8. After approximately 30 minutes, if
regeneration is completed,
press the Reset button to reset the amount
of used softened water counter. (When
regeneration is completed, the timer sound
stops and the switching valve is set to the
‘Complete position.)
9. Set the switching valve to ‘Soft Water,
check that no water is leaking and close the
top cover.
REGENERATION
Maintenance
14
13
- Never close the faucet while regeneration. If regeneration does not complete
successfully, the regeneration eciency may decrease or malfunction.
- Make sure to use a dedicated recycler. Failing to do so may decrease the regeneration
eciency.
- Do not use Tap water or ‘Soft water’ while the regeneration process is in progress.
If you turn the Tap water or ‘Soft water’ on before the end of the regeneration cycle,
you will need to restart the cycle again from the beginning.
- Turning the soft water on before the regeneration cycles ends can harm the
eectiveness of the softened water.
Tips
Make sure to place the shower head on the oor to let the
regenerating water drained away through the shower head.