Product installation
Coway co., Ltd
3-3
Flushing the filters (when installing the product, replacing the filter or providing customer service)
- Neo-sense filter/Innocence filter
: Close the valve (feed water valve) of the installation adapter.
Separate
the product and the feed water line.
Connect
the tube connected to the installation adapter to the filter to be flushed.
Open
the feed water valve to flush the filter. (1 min)
Never
tap the filter to prevent damage to the block.
- Membrane filter (RO)
: Close the valve (feed water valve) of the installation adapter.
Separate
the product and the feed water line.
Connect
the tube connected to the installation adapter to the filter to be flushed.
Install
the non-potable water valve to the membrane filter. (It is installed by default.)
Open
the feed water valve to flush the filter. (5 min)
- Membrane filter (UF)
: Close the valve (feed water valve) of the installation adapter.
Separate
the product and the feed water line.
Connect
the tube connected to the installation adapter to the filter to be flushed.
Open
the feed water valve to flush the filter. (3 min)