Disassembling and refitting
Coway co., Ltd
4-7
4-2-4 Disassembling the Room Water-Faucet Assembly, Room Water-Valve
Assembly and CTS Water Level-Sensor Assembly
No. Part names Description Reference picture
1 Room
Water-
Faucet
Assembly
1)
Remove the 2 screws from the
Room Water-Faucet Assembly.
:
2-THT 4X12
2) Separate the Room Water-
Faucet Assembly by pulling it
in the direction of the arrow as
shown in the figure.
2 Room
Water-Valve
Assembly
1)
Remove the 2 screws from the
Room Water-Valve Assembly.
: 2-THT 4X12
2) Separate the Room Water-Valve
Assembly by pulling it in the
direction of the arrow as shown
in the figure.