Troubleshooting
Coway co., Ltd
5-9
Function Detailed operation
2.
W
ater level
and valve
control
5)
Extraction valve control (fixed amount extraction function)
- If the extraction button is pressed, the extraction valve is turned on and
approximately 1,000 cc of water is extracted.
: The function is only selected when the input continues for 1 second
:
The function is only canceled when the input continues for 0.1 seconds:
- If the extraction button is pressed, the beeper sound (ding~) is heard.
- The fixed amount extraction function only works when the water level is mid
or higher.
: If the fixed amount extraction function is available, the indicator LED is
turned on to indicate that the extraction function is available.
: If the extraction button is pressed when the water level is low, the alarm
beeper sound (ding ding ~~) is heard indicating that the extraction function
is not available.
- While extracting, the indicator LED blinks at 1 second intervals to indicate that
water is being extracted.