We see temperature and temperature differences!!!
▶ Check RS-485 communication setting including
ID.
※ RS-485 communication initial setting(factory default)
10. Product specification
LWIR, Uncooled a-Si micro-bolometer
Thermal sensitivity(NETD)
Operating conditions
(Ambient temperature)
-10℃ to 60℃
(Installing camera inside housing with built-in fan and heater keeping
inside housing at a certain temperature range, for example, between
15℃ and 25℃, to have better accuracy in temperature measurement,
in case camera is installed in the open air)
Temperature detection mode
Normal temperature detection mode: -20 ~ 120℃
High temperature detection mode(Dual): 0 ~ 650℃ (-20 ~ 120℃)
Protocol for menu control
Pelco-D , SAMSUNG-T, THERMAL Protocol
Standard BNC connector(Composite), HDMI connector
BNC connector Composite): NTSC 30Hz, PAL 25Hz
HDMI: 50Hz or 60Hz (selectable)
Giga Ethernet(10/100/1000Mbps)
(Use Giga Ethernet cable as per CAT6 standard)
AC(110 ~ 220V) to DC(12V) Adaptor included in the package
Thermal imaging analyzer:
Get temp. raw data from camera and execute various analysis on
PC(1:1 connection)
Camera controller: Access to camera via IP network to control camera