8
Polarity Automatic (no indication for
positive); Minus (-) sign for negative
Measurement Rate 2 times per second, nominal
Low Battery Indication is displayed if battery voltage
drops below operating voltage
Battery One 9 volt (NEDA 1604) battery
Fuses mA, µA ranges; 0.5A/1000V
ceramic fast blow
A range; 10A/1000V ceramic fast
blow
Operating Temperature 41F to 104F (5C to 40C)
Storage Temperature -4F to 140F (-20C to 60C)
Operating Humidity Max 80% up to 87F (31C)
decreasing linearly to 50% at 104F
(40C)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Weight 0.753lb (342g) (includes holster).
Size 7.2” x 3.2” x 2.2” (182 x 82 x 55mm)
Safety This meter is intended for origin of
installation use and protected,
against the users, by double
insulation per EN61010-1 and
IEC61010-1 2
nd
Edition (2001) to
Category IV 600V and Category III
1000V; Pollution Degree 2. The
meter also meets UL 61010-1, 2
nd
Edition (2004), CAN/CSA C22.2 No.
61010-1 2
nd
Edition (2004), and UL
61010B-2-031, 1
st
Edition (2003)
Approvals UL CE
UL Listed The UL mark does not indicate that
this product has been evaluated for
the accuracy of its readings.