EasyManuals Logo
Home>Crane>Merchandiser>Coca-Cola BevMAX Refresh

Crane Coca-Cola BevMAX Refresh User Manual

Crane Coca-Cola BevMAX Refresh
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8 of 29
Cab Control” Cabinet Controller Summary Error Codes
Press key number 4 and the display will show one of the following:
- C Test Cup Board factory test not completed.
- E Test Environmental Board factory test not completed
- P Test Port Board factory test not completed.
- X Test X Motor Board factory test not completed.
- Y Test Y Motor Board factory test not completed.
- C Comms Cup Board Communication issue.
- E Comms Environmental Board Communication issue.
- P Comms Port Board Communication issue.
- X Comms X Motor Board Communication issue.
- Y Comms Y Motor Board Communication issue.
- C Reset Cup Board reset unexpectedly
- E Reset Environmental Board reset unexpectedly.
- P Reset Port Board reset unexpectedly.
- X Reset X Motor Board reset unexpectedly.
-Y Reset Y Motor Board reset unexpectedly
-CC Power Cabinet Controller Power issues. Usually means none of the cabinet controllers have power.
Press key number 1 will return to “Control Systemif all control system Error Codes have not been cleared. If all control
system Error Codes have been cleared the next error code will be displayed, or “No Error Codes” if there are no Error
Codes. Press key number 1 will return to “Error Codes”.
“CHANGER- Changer Summary Error Codes
Press key number 4 and the display will show one of the following:
- Changer Comm”, indicating a changer communication error (No communication for more than 2 seconds).
- Tube Sense”, indicating a tube sensor error.
- Changer Inlet”, indicating an inlet chute blocked error (no coins sensed in acceptor for 96 hours).
- Tube Jam #”, indicating a tube jam error.
- Changer ROM”, indicating a changer ROM check sum error (failed changer).
- Excessive Escrow”, indicating excessive escrow attempts (more than 255 since last coin sensed).
- Coin Jam”, indicating a coin jam reported by coin mech.
- Low Acceptance”, indicating a low coin acceptance rate (less than 80%).
- Acceptor Disconnected”, indicating an acceptor is unplugged.
- Coin Routing Err”, indicating a coin was miss-routed.
Press key number 1 will return to “CHANGERif all changer Error Codes have not been cleared.
If all changer Error Codes have been cleared the next error code will be displayed or “No Error Codesif there are no
Error Codes. Press key number 1 will return to “Error Codes”.
“Bill Validator” - Bill Validator Summary Error Codes
Press key number 4 and the display will show one of the following:
- Bill Val Comm” indicating a bill validator communication error (No communication for more than 5 seconds).
- Bill Stack Full” indicating the bill stacker is full.
- Bill Motor Errorindicating a defective motor in the validator.
- Bill Jam ” indicating a bill jam in the validator.
- Bill Val ROM” indicating a check sum error.
- Bill Stack Openindicating an open stacker.
- Bill Sense Err” indicating a bill validator sensor error.
Press key number 1 will return to “Bill Validatorif all changer Error Codes have not been cleared.
If all validator Error Codes have been cleared the next error code will be displayed or “No Error Codes” if there are
no Error Codes.
Press key number 1 will return to “Error Codes”.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crane Coca-Cola BevMAX Refresh and is the answer not in the manual?

Crane Coca-Cola BevMAX Refresh Specifications

General IconGeneral
BrandCrane
ModelCoca-Cola BevMAX Refresh
CategoryMerchandiser