8. The mains cable entry and terminal block will be visible on the right hand side of the unit.
Insert the mains cables through the cable gland at the bottom of the heater in readiness for
connection (Fig. 8).
IMPORTANT - Only heat resistant ordinary polyvinyl chloride sheathed exible cord should be
used, the following codes apply;
IEC - 60227 IEC57 or CENELEC - H05V2V2-F
Maximum Cable Sizes
Peak mains cable 1.5mm²
O-peak mains cable 2.5mm²
WARNING - Maximum torque 0.5 Nm
WARNING: All electrical connections to the terminal block must be secure to prevent risk of
ignition.