INSTALLATION AND START UP
· Machine positioning
MIN. 10 cm
MIN. 30 cm
Install within 0-3º horizontal.
1. Installing the machine in the service area must be performed by a qualied person. As the
machine may be quite heavy, at least two strong, capable individuals are recommend to work
together to lift and position the machine. Consult the Technical Specications page for the
specic machine model being installed for machine weight and dimensions details. Contact a
service technician to do this task if you are not condent about performing the steps below.
2. Position the machine on a level, sturdy, and water-resistant surface approximately 110cm (43
inch) above oor level for ease of access and usage.
3. Adjust the feet to ensure that it dispenses coee evenly to all cups.
4. Ensure enough free space is available above (>30cm / >12inch) and behind (>10cm / 3.94 inch)
the machine to ensure easy cleaning and maintenance and adequate ventilation.
Important:
Leave an air gap of at least 30cm (11.8 inch) above the machine and 10cm (3,94 inch) behind
it to ensure adequate ventilation. The machine must be installed within 3º of horizontally level
front-to-back and side-to-side to ensure proper hydraulic function and drainage. Conrm with
a spirit level or digital angle gauge.
Do not install the machine if the machine or installation surface it is wet. Allow it to dry
completely and ask a service technician to ensure that none of the electrical components have
been aected.