Original instructions.
INSTALLATION AND START UP
· Electrical connection checklist
DANGER!
If the mains cable or plug is damaged, it
must be replaced by the manufacturer,
its service agent or similarly qualied
persons in order to avoid a hazard.
1. The machine must only be connected to the power supply by qualied personnel. The
following safety instructions must be obeyed at all times.
2. Ensure that the electrical requirements stated on the TECHNICAL SPECIFICATIONS and on the
ratings plate located under the drip tray inside the machine match the specications of the
power supply.
3. Ensure that the domestic electrical supply where the machine is being installed is rated for
and able to provide the power required by the machine. Insucient power supply, wiring,
grounding, or insulation can result in overheating and possibility of re.
4. The coee machine must be connected to an earth grounded electrical outlet that complies
with the regulations in force in the country of installation. For appliances not tted with a
supply cord and a plug, means for disconnection must be incorporated in the xed wiring in
accordance with the wiring rules.
5. Ensure that a circuit breaker engineered for the power consumption of the machine is
installed to protect the electrical supply, as specied on the ratings plate located under the
drip tray.
6. Never connect the machine to the power supply via extension cords, plug adapters, or shared
outlets.
Important:
The manufacturer will not be held liable for
damage to persons, animals or property
resulting from incorrect installation of the
coee machine.
Machine: 220V-240V 1N~
Machine: 380V-415V 3N~
Machine: 380V-415V 2N~
Bl
ue
Brown
NEUTRAL
PHASE
Yellow/Green
Supply cable
GROUND
Blue
Grey
NEUTRAL
PHASE
Yellow/Green
Supply cable
Black
GROUND
PHASE
Blue
Grey
NEUTRAL
PHASE
Yellow/Green
Supply cable
Black
GROUND
PHASE
Brown
PHASE