13
· Sb – PID band zone
To change the PID band zone, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [Sb] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the PID working band value.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
SERVICE PROGRAMMING
· SE – Display temperature oset
To change the home Display temperature oset, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [SE] is shown on the display, enter by pressing K5.
3. Select with K1 and K2 the Display temperature oset.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
· AUt – Enabling/Disabling Auto On/O function
To enable or disable the Auto On/O function, follow the steps below:
1. Enter the service programming and browse through the menu (see previous instructions).
2. When [AUt] is shown on the display, enter by pressing K5.
3. Use K1 and K2 to enable [on] or disable [oFF] the Auto On/O function.
If enabled [on], press K5 and the machine will ask for the close day [00X].
Weekdays: [001] Monday; [002] Tuesday; … ; [007] Sunday.
4. Accept and save setting by pressing K5. You are back in the service programming menu.
i
Note:
The temperature shown on the display at home screen will be the boiler temperature
read by the temperature probe minus the [SE] value. E.g.: If Tboiler = 116ºC and
[SE] = 20, the value shown on the display will be Tboiler – [SE] = 116 – 20 = [ 96]
i
Note:
The Auto On and O timers are adjusted on User menu when the function is enabled
in service menu.