· Alarms and warnings
To alert users that routine service of the machine is due or against a situation that could possibly cause
damage to the machine, EX3 has the following alerts programmed into its software:
Display
Code
Machine status Alarm Name
Warning
/ Alarm
Solution
[AL1]
Machine blocked and all
touchpads buttons blink
NTC is short-
circuited
Alarm Call a service specialist to replace it
[AL2]
Machine blocked and all
touchpads buttons blink
NTC is not con-
nected
Alarm Call a service specialist to replace it
[AL3]
Selected button blinks
and brew must be
stopped manually
No ow detected
on this group
Warning Call a service specialist
[FiL]
Machine blocked and all
touchpads buttons blink
Steam Boiler
FillingUp timeout
Alarm
Turn the main switch o and on again.
Check that the machine is receiving water
[Eco]
Touchpads lights o
Boiler temperature is
decreased to 105ºC
Eco mode status Warning
Press any button from K1 to K4 to ’wake up’
the machine
[oFF]
Touchpads lights o
Boiler element
disconnected
Stand-by mode
status
Warning
Press any button from K1 to K4 to ’wake up’
the machine
[SEr]
Machine works
Static message on group 1
Service
maintenance
alarm
Warning
Call service specialist to perform
maintenance routine.
To reset the service alarm counter:
- Keep pressed K1+K2 and turn the machine
on by the main switch.
- Message [rSE] will be shown on Group 1
[FiL]
Machine works
Static message on group 1
Water lter
maintenance
alarm
Warning
Call service specialist to perform
maintenance routine.
To reset the service alarm:
- Keep pressed K3+K4 and turn the machine
on by the main switch.
- Message [rFi] will be shown on Group 1