16
English
DIVE-SET: Setting dive parameters.
AIR/NITROX (DONATELLO), NITROX GAS1-2 (MICHELANGELO),
NITROX GAS 1-2-3 (RAFFAELLO)
OncetheMODESET(MODE-S)menuhasbeensetintheAIRandNITROXmode,
itsparameterscanbeeditedbyaccessingtheDIVESET(DIVE-S)menu.
PressthebuttonLong
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
toaccessthedive-setmenu.
TheparametersthatcanbeeditedintheDIVE-SmenuinAIR/NITROXmodes
areasfollows:
DEEPSTOP - SAFETY FACTOR (SF) - ALTITUDE (ALT)- DEPTH (MAXIMUM
DEPTH ALARM) - OXYGEN PERCENTAGE (%O2 NITROX MODE) - PARTIAL
PRESSUREOFOXYGEN(PPO2)- OXYGENPERCENTAGEGAS2(OFF/21%-
99% MICHELANGELO/RAFFAELLO ONLY). PARTIAL PRESSURE GAS2
(MICHELANGELO/RAFFAELLO ONLY) - OXYGEN PERCENTAGE GAS 3
(OFF/21%-99%RAFFAELLOONLY)-PARTIALPRESSUREGAS3(RAFFAELLO
ONLY)–
DEEP STOP
There are different diving teaching methodologies and decompression theories.
Each of them has been developed according to important scientific concepts, lab
tests and practical tests. During specific dives, some of them support and require
DEEP STOPs, while others do not call for this type of decompression prole.
DONATELLO/MICHELANGELO/RAFFAELLOisfactorysetwithDEEPSTOPactive.
TheDEEPSTOPiconindicatesthatitisactive.PressthebuttonLong
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
, then
a Short
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press to activate/deactivate the deep stop, followed by another
Long
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press until you hear the confirmation beep.
SF (SAFETY FACTOR)
TheSafetyFactoris anadditionalparameterwhose purposeisto makedives
safer based on when there are personal risk factors that increase the risk of
decompressionsickness.Thedivercanselectfromthreevalues:SF0/SF1/SF2.
ThedefaultfactorysettingisSF0,i.e.disabled.
TochangetheSafetyFactor(SF),Long
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press the button and adjust the
safetyfactortothedesiredsettingwithaShort
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press(SF0/SF1/SF2).
ConrmwithaLong
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press until you hear the confirmation beep.
ALT (ALTITUDE)
Fordivestakenataltitude,adjustthecomputerasfollows:GivethebuttonaLong
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press, and then a Short
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
one to adjust the correct altitude value. Give
the button a Long
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press until you hear the confirmation beep.
Nomountain -from0to2297ft(0to700m)
Onemountain -from2297to4921ft(700to1500m)
Twomountains -from4921to7874ft(1500to2400m)
Threemountains -from7874to12139ft(2400to3700m)